Commit Graph

1052 Commits

Author SHA1 Message Date
Dominik Csapak
844d8fa628 move the vmgenid device after readconfig on q35
and adapt the tests

this does not impact live migration, since the order here does not
change the device layout

we want this to consistently have the readconfig first

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2020-01-31 20:26:26 +01:00
Oguz Bektas
74f15a8993 hotplug_pending: make 'ssd' option non-hotpluggable
from hotplug_pending we go into 'vmconfig_update_disk', where we check the
hotpluggability of options.

add 'ssd' there as a non-hotpluggable option (since we'd have to unplug/plug to
change the drive type)

Signed-off-by: Oguz Bektas <o.bektas@proxmox.com>
2020-01-24 16:11:53 +01:00
Stefan Reiter
d786a27435 Add CPUConfig file and migrate some helpers
The package will be used for custom CPU models as a SectionConfig, hence
the name. For now we simply move some CPU related helper functions and
declarations over from QemuServer to reduce clutter there.

Exports are to avoid changing all call sites, functions have useful
names on their own.

Signed-off-by: Stefan Reiter <s.reiter@proxmox.com>
2020-01-22 15:47:32 +01:00
Fabian Ebner
301c675281 Use 'volname' instead of 'volid' for 'qemu_img_format'
As 'qemu_img_format' just matches a regex, this doesn't make much of
a difference, but AFAICT all other calls of 'qemu_img_format' use 'volname'.

Signed-off-by: Fabian Ebner <f.ebner@proxmox.com>
2020-01-21 07:45:31 +01:00
Fabian Ebner
c3c5d2b6b3 Fix 2070: vm_start: for a migrating VM, use current format of disk if possible
Signed-off-by: Fabian Ebner <f.ebner@proxmox.com>
2020-01-21 07:45:31 +01:00
Oguz Bektas
3d48b95aa8 vmconfig_apply_pending: remove redundant write/load config calls
since we handle errors gracefully now, we don't need to write & save
config every time we change a setting.

Signed-off-by: Oguz Bektas <o.bektas@proxmox.com>
2020-01-16 10:29:31 +01:00
Tim Marx
ef3f42930f add timeout parameter to vm_start api endpoint
Signed-off-by: Tim Marx <t.marx@proxmox.com>
2020-01-15 17:36:16 +01:00
Tim Marx
2f18c84dc7 add new helper to calculate timeout based on vm config
Signed-off-by: Tim Marx <t.marx@proxmox.com>
2020-01-15 17:36:16 +01:00
Stefan Reiter
52cffab6b5 Fixup CPU flag query to not use get_basic_machine_info
get_basic_machine_info was removed by commit 045749f2fc.

Use get_host_arch to get the default machine type instead, and
optionally allow to specify architecture as parameter.

Signed-off-by: Stefan Reiter <s.reiter@proxmox.com>
2020-01-15 15:57:00 +01:00
Stefan Reiter
05a4c550f3 Add QEMU CPU flag querying helpers
* query_understood_cpu_flags returns all flags that QEMU/KVM knows about
* query_supported_cpu_flags returns all flags that QEMU/KVM can use on
  this particular host.

To get supported flags, a temporary VM is started with QEMU, so we can
issue the "query-cpu-model-expansion" QMP command. This is how libvirt
queries supported flags for its "host-passthrough" CPU type.
query_supported_cpu_flags is thus rather slow and shouldn't be called
unnecessarily.

Note that KVM and TCG accelerators provide different expansions for the
"host" CPU type, so we need to query both.

Currently only supports x86_64, because QEMU-aarch64 doesn't provide the
necessary querying functions.

Signed-off-by: Stefan Reiter <s.reiter@proxmox.com>
2020-01-14 11:56:21 +01:00
Oguz Bektas
eb5e482ded vmconfig_apply_pending: add error handling
wrap around code which can possibly fail in evals to handle them
gracefully, and log errors.

note: this results in a change of behavior in the API. since errors
are handled gracefully instead of "die"ing, when there is a pending
change which cannot be applied for some reason, it will get logged in
the tasklog but the vm will continue booting regardless. the
non-applied change will stay in the pending section of the
configuration.

Signed-off-by: Oguz Bektas <o.bektas@proxmox.com>
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2020-01-14 11:50:34 +01:00
Oguz Bektas
4df15a0377 hotplug_pending: remove redundant write/load config calls
instead of writing the config after every change, we can do it once for
all the changes in the end to avoid redundant i/o.

we also don't need to load_config after writing fastplug changes.

Signed-off-by: Oguz Bektas <o.bektas@proxmox.com>
2019-12-20 10:51:52 +01:00
Thomas Lamprecht
ae200950d4 grammar fix: s/does not exists/does not exist/g
bump versioned build-dependency, as qemu-server has tests checking
for errors, and we fixed an grammar error in pve-storage, so we need
the newer version to ensure our test go through

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-12-13 12:20:56 +01:00
Thomas Lamprecht
128193e26a followup: simplify log callback
run_command only passes defined and chomped strings to the callback,
so no need to do that twice.

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-12-12 13:39:04 +01:00
Stefan Reiter
8bf30c2a72 fix #2493: show QEMU errors in migration log
QEMU usually only prints warnings and errors and stays silent otherwise,
so it makes sense to just log all of it's output.

Prefix it with '[<target_hostname>]' to indicate that the output is
coming from the remote node, so users know where to search for the
error.

Side effect is that the 'VM start' task created by the migration will
now show the "QEMU:" prefix, but it's still very readable IMHO.

Signed-off-by: Stefan Reiter <s.reiter@proxmox.com>
2019-12-12 13:36:19 +01:00
Stefan Reiter
6e0216d862 hide long commandline on vm_start/migrate failure
By default run_command prints the entire commandline executed when an
error occurs, but QEMU and our migrate command are not only
uninteresting to the user[*] but also annoyingly long. Hide them and only
print the exit code.

[*] Especially our migrate command, since it can't be manually executed
anyway. QEMU's commandline *might* contain something interesting, but is
so long that it's tricky to parse anyway, any a user can always call 'qm
showcmd --pretty'.

Signed-off-by: Stefan Reiter <s.reiter@proxmox.com>
2019-12-12 13:35:40 +01:00
Stefan Reiter
68b108ee3a update disk size before local disk migration
Split out 'update_disksize' from the renamed 'update_disk_config' to
allow code reuse in QemuMigrate.

Remove dots after messages to keep style consistent for migration log.

After updating in sync_disks (phase1) of migration, write out updated
config. This means that even if migration fails or is aborted in later
stages, we keep the fixed config - this is not an issue, as it would
have been fixed on the next attempt anyway, and it can't hurt to have
the correct size instead of a wrong one either way.

Signed-off-by: Stefan Reiter <s.reiter@proxmox.com>
2019-12-11 10:42:56 +01:00
Dominik Csapak
75c24bba0a suspend to disk: check more permissions
only VM.PowerMgmt is not enough, since we allocate space on a storage,
so we need VM.Config.Disk on the vm and Datastore.AllocateSpace on the storage

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2019-12-11 09:02:55 +01:00
Dominik Csapak
66cebc4671 refactor finding of vmstate storage
we need that on another place, so refactor in its own sub

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2019-12-11 09:02:55 +01:00
Thomas Lamprecht
38277afcd4 qemu-server: make nodename mock-able for tests
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-12-10 11:08:33 +01:00
Thomas Lamprecht
cbb39a7e79 followup: improve error message for outdated QEMU version
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-12-10 11:08:33 +01:00
Stefan Reiter
a77a53ae54 check if QEMU version is recent enough for machine type
...and show the user a more meaningful error otherwise.

Signed-off-by: Stefan Reiter <s.reiter@proxmox.com>
2019-12-10 09:13:33 +01:00
Stefan Reiter
71c58bb7ed remove $vmid param from print_drive
It isn't used in the sub, but suggest it is needed. No users outside
qemu-server found.

Signed-off-by: Stefan Reiter <s.reiter@proxmox.com>
2019-12-09 11:44:13 +01:00
Thomas Lamprecht
c7728fdb85 followup: minor cleanup/error message spelling
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-12-09 11:30:14 +01:00
Dominik Csapak
844b55fb89 fix #2510: hostpci: always check if device exists
if the user set a device as hostpci with the 'shorthand' syntax:

hostpciX: 00:12

we ignored it on starting and showcmd and continued.
Since the user explicitly wanted to passthrough a device, we now check
if there is actually a device with that id

for explicitly configured devices (00:12.1), we did not check if it exists,
but the kvm call failed with a non-obvious error message

now we always call 'lspci' from SysFSTools to check if it actually exists,
and fail if not. With this, we can drop the workaround for adding
'0000' if no domain was given, since lspci does it already for us

this fixes #2510, an issue with using mediated devices where the users did not have
the domain in the config, since we forgot to add the default domain there

the only issue with this patch is that it changes the behaviour of
'showcmd' slightly, as in now, we die if the device was explicitly
given, but did not exists (we showed the commandline, now we fail)

this also slightly changes the commandline for qemu (adding always
the domain), which is not a problem since we cannot live migrate
or snapshot such vms, but we have to adapt the tests

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2019-12-09 11:30:14 +01:00
Thomas Lamprecht
bdd1feef5b fix #2469: fix qemu-img convert src_format detection
This reverts commit c5151cb8bb which is
a revert of the wrongly done revert of
commit e2414e73ce.
2019-12-09 10:31:33 +01:00
Thomas Lamprecht
340dbcf730 create_efidisk: poll the real size after volume creation
some storage backends have bigger granularity than the default 128k
size from the EFIVARS template file, so we actually need to poll the
real created disk size, as it will be used to create the target
volume for local storage migration on running VMs, if it's to small
the target will be to small and migration will fail.

Just a fix for newly created EFIDISKS, for others we need to rescan
the size after we've got the migrate lock and write the updated info
out, so that the target node has the correct one (protected from
migrate lock).

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-12-04 18:42:27 +01:00
Dominik Csapak
ad1d49f45c delete suspended lock when we have no vmstate
if a user removed the vmstate from the config for whatever reason,
a vmstart did not remove the 'suspended' lock
so always delete it and delete the vmstate only if it really was there

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2019-11-30 17:28:23 +01:00
Dominik Csapak
b85666cf7f logging vmstate into Resume/Start Task
so that the user knows what got loaded as vmstate

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2019-11-30 17:28:23 +01:00
Oguz Bektas
7a4bdb3662 skip efidisk0 in hotplug
while it's a disk from our storage POV, in QEMU it's a pflash, and
those cannot be hot-plugged

Signed-off-by: Oguz Bektas <o.bektas@proxmox.com>
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-11-26 17:11:49 +01:00
Thomas Lamprecht
c5151cb8bb Revert "fix #2469: fix qemu-img convert src_format detection"
This reverts commit e2414e73ce.
2019-11-26 13:06:57 +01:00
Thomas Lamprecht
9471e48bf9 implement PVE Version addition for QEMU machine
With our QEMU 4.1.1 package we can pass a additional internal version
to QEMU's machine, it will be split out there and ignored, but
returned on a QMP 'query-machines' call.

This allows us to use it for increasing the granularity with which we
can roll-out HW layout changes/additions for VMs. Until now we
required a machine version bump, happening normally every major
release of QEMU, with seldom, for us irrelevant, exceptions.
This often delays rolling out a feature, which would break
live-migration, by several months. That can now be avoided, the new
"pve-version" component of the machine can be bumped at will, and
thus we are much more flexible.

That versions orders after the ($major, $minor) version components
from an stable release - it can thus also be reset on the next
release.

The implementation extends the qemu-machine REGEX, remembers
"pve-version" when doing a "query-machines" and integrates support
into the min_version and extract_version helpers.

We start out with a version of 1.

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
Reviewed-by: Stefan Reiter <s.reiter@proxmox.com>
2019-11-25 16:43:38 +01:00
Fabian Grünbichler
e2414e73ce fix #2469: fix qemu-img convert src_format detection
if we don't know which format the source volume/file has, let qemu-img
decide.

Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-11-25 13:45:46 +01:00
Fabian Grünbichler
d184401e9f remove wrong comment
the change to encode pending changes differently is not yet included in
qemu-server.

Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
2019-11-25 10:38:15 +01:00
Oguz Bektas
15c6e277a4 fix #2367: do not allow snapshot with name PENDING
or any other variant of the word 'pending'.

note that we can actually allow this snapshot after PVE 7.0, since
pending section and snapshots will be properly namespaced.
([pve:pending] and [snap:$snapname] or similar).

Signed-off-by: Oguz Bektas <o.bektas@proxmox.com>
2019-11-25 10:01:41 +01:00
Thomas Lamprecht
045749f2fc split get_basic_machine_info into get_vm_arch and get_vm_machine
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-11-25 08:56:58 +01:00
Thomas Lamprecht
eec4f394f9 really fallback to PCI standard domain "0000" again
fixes commit 70740c1a4d

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-11-23 09:50:54 +01:00
Dominik Csapak
b8e7068a11 add 'tags' option
this is useful as meta information for e.g., provisioning or config
management systems

adding the info also to the 'status' api call to make it easier to show
it in the gui

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2019-11-20 20:24:49 +01:00
Dominik Csapak
70740c1a4d fix #2436: pci: do not hardcode pci domain to 0000
relax the regex for hostpci to allow different pci domains than 0000

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2019-11-20 19:07:46 +01:00
Thomas Lamprecht
6c9f59c122 cleanup: improve locallity of variable declaration/use
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-11-20 19:06:15 +01:00
Stefan Reiter
2ea5fb7ecf refactor: split qemu_machine_feature_enabled
...into:

* PVE::QemuServer::Helpers::min_version: check a major.minor version
  string with a given major/minor version (this is equivalent to calling
  the old qemu_machine_feature_enabled with only $kvmver)
* PVE::QemuServer::Machine::extract_version: get major.minor version
  string from arbitrary machine type (e.g. pc-q35-4.0, ...)
* PVE::QemuServer::Machine::machine_version: helper to call
  extract_version automatically before min_version

Includes a cfg2cmd test case with pinned machine version.

Signed-off-by: Stefan Reiter <s.reiter@proxmox.com>
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-11-20 18:32:35 +01:00
Stefan Reiter
3392d6cacf refactor: extract QEMU machine related helpers to package
...PVE::QemuServer::Machine.

qemu_machine_feature_enabled is exported since it has a *lot* of users
in PVE::QemuServer and a long enough name as it is.

Signed-off-by: Stefan Reiter <s.reiter@proxmox.com>
2019-11-20 16:29:23 +01:00
Stefan Reiter
0a13e08ec2 refactor: create QemuServer::Monitor for high-level QMP access
QMP and monitor helpers are moved from QemuServer.pm.

By using only vm_running_locally instead of check_running, a cyclic
dependency to QemuConfig is avoided. This also means that the $nocheck
parameter serves no more purpose, and has thus been removed along with
vm_mon_cmd_nocheck.

Care has been taken to avoid errors resulting from this, and
occasionally a manual check for a VM's existance inserted on the
callsite.

Methods have been renamed to avoid redundant naming:
* vm_qmp_command -> qmp_cmd
* vm_mon_cmd -> mon_cmd
* vm_human_monitor_command -> hmp_cmd

mon_cmd is exported since it has many users. This patch also changes all
non-package users of vm_qmp_command to use the mon_cmd helper. Includes
mocking for tests.

Signed-off-by: Stefan Reiter <s.reiter@proxmox.com>
2019-11-20 16:29:23 +01:00
Stefan Reiter
babf613a08 refactor: split check_running into _exists_ and _running_
vm_exists_on_node in PVE::QemuConfig checks if a config file for a vmid
exists

vm_running_locally in PVE::QemuServer::Helpers checks if a VM is running
on the local machine by probing its pidfile and checking /proc/.../cmdline

check_running is left in QemuServer for compatibility, but changed to
simply call the two new helper functions.

Both methods are also correctly mocked for testing snapshots.

Signed-off-by: Stefan Reiter <s.reiter@proxmox.com>
2019-11-20 16:29:23 +01:00
Stefan Reiter
24622ebed4 Change check_cmdline to parse_cmdline
parse_cmdline is required for upcoming changes related to custom CPU
types and live migration, and this way we can re-use existing code.

Provides the necessary infrastructure to parse QEMU /proc/.../cmdline.
Changing the single user (check_running) is trivial too.

Signed-off-by: Stefan Reiter <s.reiter@proxmox.com>
2019-11-20 16:29:23 +01:00
Stefan Reiter
d036e418a8 refactor: create QemuServer::Helpers and move file/dir code
Also remove unused $confdir variable in QemuConfig, but leave it and
$lock_dir there, since those paths should only be used with
cfs_config_path anyway.

nodename() is still called in multiple places, but since it's cached by
INotify it doesn't really matter.

Signed-off-by: Stefan Reiter <s.reiter@proxmox.com>
2019-11-20 16:29:23 +01:00
Stefan Reiter
60f03a1168 Fix 'uninitialized value' warning about guest agent type
Signed-off-by: Stefan Reiter <s.reiter@proxmox.com>
2019-11-20 16:11:44 +01:00
Stefan Reiter
092868c4d1 Add 'runningmachine' support to vm_commandline
to allow 'qm showcmd --snapshot ...' to show the correct machine type.

Signed-off-by: Stefan Reiter <s.reiter@proxmox.com>
2019-11-20 16:11:44 +01:00
Thomas Lamprecht
5084a85941 qemu: remove unused methods
found no use with tree-wide search, so remove:
* nic_models
* os_list_description

Both were introduced before the import to SVN happened.

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-11-20 15:37:01 +01:00
Thomas Lamprecht
9e8976ea4e followup: adding qxl max_outputs breaks live-migration/restore
enforce QEMU 4.1.x for that change

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-11-20 15:33:48 +01:00
Thomas Lamprecht
c5a4c92cd9 qxl max_outputs: ostype can be undefined, assume linux
Out code behaves like either l26 or other when the ostype is
undefined, both are not common as our webinterface _always_ sets the
ostype.

If one configured QXL with a VM as output device but does not has an
ostype set, and that works without "max_outputs=4" it really should
work with none too.

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-11-20 15:29:12 +01:00
Aaron Lauterer
6021c7a5ed print_vga_device: fix qxl displays on Linux guests
with pve-qemu-4.0.1-3 or higher it was not possible in a spice remote
session to enable more displays on the fly in linux guests.

Adding the `max_outputs` parameter to the qxl device manually restores
the functionality.

Signed-off-by: Aaron Lauterer <a.lauterer@proxmox.com>
2019-11-20 15:05:43 +01:00
Thomas Lamprecht
9a9ba5f857 get_cpu_options: reuse ostype variable
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-11-20 15:05:43 +01:00
Thomas Lamprecht
a52692609c ostype: update verbose description
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-11-20 15:05:43 +01:00
Thomas Lamprecht
7fe8b44c54 clone: pre-create cloud-init disk for destination
While we may not want to copy the cloudinit disk/drive, we still need
to create+allocate the volume, else the next start complains about a
missing CI drive..

fixes commit 7d6c99f0a0.

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-11-19 10:29:58 +01:00
Wolfgang Bumiller
e5a66e48ba avoid cyclic reference
this otherwise leaks memory

Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2019-11-19 09:26:45 +01:00
Matt Dunwoodie
4865715861 Add 'type' to agent_fmt
This adds an extra field to agent_fmt that specifes the type of guest
agent connection to use. Currently there is no choice, and defaults to
virtio-serial. Since qemu-ga also runs over isa-serial, this allows OSes
such as NetBSD and OpenBSD, which do not have support for virtio-serial,
to run a qemu-ga.

This is an optional field, which leaves the default as virtio-serial. As
it doesn't change the default, it will require no change to older
configuration files.

Signed-off-by: Matt Dunwoodie <ncon@noconroy.net>
2019-11-18 16:04:28 +01:00
Aaron Lauterer
255e9c546c api/migration: fix autocomplete for targetstorage
Show storages configured for the target node and not for the current one
because they can be different.

Duplicated the `complete_storage` sub and extended it to extract the
targetnode from the parameters to pass it into the storage_check_enabled
function.

Signed-off-by: Aaron Lauterer <a.lauterer@proxmox.com>
2019-11-18 15:42:18 +01:00
Fabian Grünbichler
b24e1ac224 refactor migration IP retrieval
since PVE::Cluster::get_local_migration_ip does not exist anymore. this
is basically an inlined version, since this is the only remaining caller
that we actually want to keep.

Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
2019-11-18 12:10:25 +01:00
Fabian Grünbichler
48cf040f75 use PVE::DataCenterConfig
to make sure that the corresponding cfs_read_file works() works.

Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
2019-11-18 12:10:25 +01:00
Dominik Csapak
8baf8bc77e fix destroy_vm by using correct Config package
We are in the QemuServer package not in LXC, so use the correct
package for the Config, namely QemuConfig

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2019-11-14 10:04:35 +01:00
Thomas Lamprecht
3c1c3fe6a1 followup: what vs. why comment
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-11-11 18:05:20 +01:00
Oguz Bektas
66026117b0 qmreboot: clear reboot request if reboot fails
the reboot request is only cleaned in the vm_start path, so if reboot
fails for some reason, the request still exists. this causes an
unintentional reboot when a shutdown/stop/hibernate is called.

to mitigate, we can just clear the reboot request in case of an error.

Signed-off-by: Oguz Bektas <o.bektas@proxmox.com>
2019-11-11 18:03:44 +01:00
Thomas Lamprecht
b04ea58453 destroy_vm: allow to pass new config and lock instead
This brings qemu more in line with containers, and it's nicer to
allow passing the replacement config if we want to keep it, instead
of setting a "memory: 128" config.

Use that to lock it on removal before final deletion, and on legacy
tar archive restore, in between old VM destruction and new
restoration.

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-11-08 17:03:30 +01:00
Thomas Lamprecht
7dc7f315f3 restore_tar_archive: cleanup
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-11-08 15:43:22 +01:00
Thomas Lamprecht
a2f50f0172 destroy_vm: refactor+cleanup and continue on unused disk removal errors
it has some potential semantic change too, i.e., the Storage
vdisk_list call is not wrapped by eval anymore, put as
we did some (unguarded) storage things before that call I'd say that
that does not matters much..

We try to clean all unused disks too, even if one deletion fails

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-11-08 15:38:23 +01:00
Thomas Lamprecht
4b0269379b followup: make comment a bit shorter/more concise
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-11-08 15:02:50 +01:00
Dominic Jäger
9b4e53889b restore_tar_archive: Add skiplock to destroy_vm
When calling qmrestore a config file is created and locked with a lock
property. The following destroy_vm has been impossible as skiplock has not
been set.

Signed-off-by: Dominic Jäger <d.jaeger@proxmox.com>
2019-11-08 14:51:49 +01:00
Fabian Grünbichler
425441e6fa move 'use UUID' statement to correct file
and add the libuuid-perl package to build-depends as well.

Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
2019-11-08 11:22:51 +01:00
Dominic Jäger
b406ab6342 replace remaining vm_destroy call-sites with destroy_vm
This function has been used in one place only into which we inlined its
functionality. Removing it avoids confusion between vm_destroy and vm_destroy.

The whole $importfn is executed in a lock_config_full.
As a consequence, for the inlined code:
1. lock_config is redundant
2. it is not possible that the VM has been started (check_running) in the
    meanwhile
Additionally, it is not possible that the "lock" property has been written into
the VM's config file (check_lock) in the meanwhile

Add warning after eval so that it does not go unnoticed if it ever comes into
action.

Signed-off-by: Dominic Jäger <d.jaeger@proxmox.com>
2019-10-29 19:11:02 +01:00
Stefan Reiter
cc111f2ab5 Use get_host_arch from PVE::Tools
...now that it no longer does LXC-specific stuff. Removes a FIXME.

Signed-off-by: Stefan Reiter <s.reiter@proxmox.com>
2019-10-29 16:05:37 +01:00
Thomas Lamprecht
0600c3bf07 runs_at_least_qemu_version: propagate QMP errors
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-29 15:58:42 +01:00
Dominik Csapak
84a50d6ef0 fix #2434: extend machine regex
with qemu 4.0.1, there is now a machine type pc-q35-4.0.1 which does not fit
into our regex

this broke live migration of q35, as we give the machine type (incl version
info) to 'qm start' on the target node, which checks it against the
JSONSchema

to fix this, extend the regex to allow any number of version levels,
for q35, i440fx and virt (to be more future proof)

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2019-10-25 15:03:32 +02:00
Dominic Jäger
dfda979e61 destroy_vm: remove VM config *after* unused disk removal
As mentioned on the mailing list [0] disks owned by the VM and unused
disks should be removed before the config file is removed.

[0] https://pve.proxmox.com/pipermail/pve-devel/2019-October/039593.html

Signed-off-by: Dominic Jäger <d.jaeger@proxmox.com>
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-25 11:41:37 +02:00
Thomas Lamprecht
20faf21e87 cleanup: no need to prefix module for call to module-local method
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-24 10:49:19 +02:00
Thomas Lamprecht
e08553ba57 qmp_socket: remove unused "name" parameter
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-23 16:10:04 +02:00
Thomas Lamprecht
9f78b695a7 vmstatus: code cleanup: directly use load_config helper
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-23 16:09:36 +02:00
Thomas Lamprecht
dfac373fa6 remove unused method "touch_config"
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-23 15:41:59 +02:00
Thomas Lamprecht
a034e3d624 followup: code cleanup and some comments
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-23 11:39:03 +02:00
Stefan Reiter
d1cbb1a93b fix #2408, #2355, #2380: use scsi-hd backend for iSCSI as well
As mentioned in #2408, live-migrating a VM between storages that use
different scsi backends (scsi-hd, scsi-generic, scsi-block) breaks.

To fix, from QEMU 4.1 machine types onward (to not break current
behaviour any more), only use scsi-hd, as in recent versions, there is
almost no difference between the two anyway.

scsi-block (which potentially also breaks) requires a flag to be
manually set on the disk, so we can assume the user knows what they're
doing.

Signed-off-by: Stefan Reiter <s.reiter@proxmox.com>
Suggested-by: Daniel Berteaud <daniel@firewall-services.com>
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-23 11:31:23 +02:00
Thomas Lamprecht
317c55c2d1 backup: is IOThread comaptible: only check running VMs
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-23 11:28:51 +02:00
Thomas Lamprecht
48343b3f1d add runs_at_least_qemu_version to check if we can backup IOThread disks
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-23 10:47:45 +02:00
Thomas Lamprecht
19e9b30895 introduce version_cmp helper for qemu_machine_feature_enabled
will be reused for a "running KVM/QEMU version is at least" helper in
a next patch

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-23 10:38:16 +02:00
Thomas Lamprecht
24d1f93a84 fixup: vmstate: pass volid not resolved path to vollist
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-22 16:31:16 +02:00
Thomas Lamprecht
d321c4a921 followup: iterate over pending changes sorted
for a more deterministic behavior, should not change things in
practice

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-22 12:47:19 +02:00
Oguz Bektas
fb4d1ba27e pending apply/hotplug: don't hard code force to true
Each pending options has a hash value which has the 'force'
information encoded as entry. But, this can be { force => 1 } or
{ force => 0 }, so we actually need to check the value and not just
set force to the hash directly, as else we have force always truthy..

fixes a bug where 'detach' caused disks to be destroyed immediately,
because $force parameter was always true since hash is true.

Signed-off-by: Oguz Bektas <o.bektas@proxmox.com>
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-22 12:45:51 +02:00
Thomas Lamprecht
edcbf953ab fixup: VM statefile: pass volid not resolved path to vollist
We cannot activate a path, only volume IDs with activate_volumes
(duh)

fixes commit 5c1d42b7f8

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-22 11:53:58 +02:00
Oguz Bektas
98bc3aeb92 use new config helpers from guest-common for pending changes
most of the pending changes related code has been moved into
AbstractConfig, so we have to call them as class methods from QemuConfig instead.

Signed-off-by: Oguz Bektas <o.bektas@proxmox.com>
2019-10-18 18:45:27 +02:00
Thomas Lamprecht
f73ed6d10f fixup: QemuConfig->write_config doesn't takes the raw config
Thanks to Fabian for the quick notice

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-18 11:44:15 +02:00
Thomas Lamprecht
5da072fb84 QemuServer: sort and group used perl modules
group by:
* external
* pve, other package
* pve, same package

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-18 11:24:26 +02:00
Thomas Lamprecht
3361d09901 destroy_vm: use write_config from our Config module to set an "empty" config
brings us more in line with what we do in pve-container, also it's
good to not use file_set_contents directly if we have all those nice
wrapper interface methods to do things in a safe and guaranteed way.

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-18 11:22:07 +02:00
Thomas Lamprecht
5172770df7 followup: use new base config provided destroy_config method
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-18 11:20:52 +02:00
Thomas Lamprecht
5c1d42b7f8 Fix #2171: vm_start: volid based statefiles were not activated
So, while we could just make this a special case before the
config_to_command call and set the $conf->{vmstate} to the statefile
for the case were it's a valid volumeid, the special case handling
get's much easier when we do this outside of that method.

So it's basically a trade-off, and after looking far to long at all
nice revisions Alwin made for me and Fabians request, and even trying
out different approaches, it was never perfect.

But having slight code duplication over the movement mess I proposed
(as I did not had the full picture then, sorry Alwin) felt like the
slightly nicer trade off, as all worked I just use this one now, it
has very clear semantics, easy to understand and that now three lines
are duplicated is IMO irrelevant.

Co-developed-by: Alwin Antreich <a.antreich@proxmox.com>
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-17 19:20:32 +02:00
Thomas Lamprecht
8f899d734e cfg2cmd: push vmstate to volid list to ensure it gets also deactivated
the volume id list is only used to activate before real start and
deactivate later, so use it for the vmstate file too.

This not only makes config_to_command have less side effects, it also
ensures that the vmstate is deactivated again

Co-developed-by: Alwin Antreich <a.antreich@proxmox.com>
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-17 19:10:52 +02:00
Dominik Csapak
af1f1ec038 fix #2395: refactor qemu_img_convert to accept files as source
and use it also for efidisk creation and importdisk
this way we correctly handle zfs-over-iscsi options for those cases

also write tests for it

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2019-10-17 13:57:21 +02:00
Thomas Lamprecht
a447e92c09 vm_start: don't reuse migrate_port variable for storage migration
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-14 13:49:30 +02:00
Thomas Lamprecht
9066fd2635 config_to_command: remove unused variable
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-14 13:49:30 +02:00
Thomas Lamprecht
311e92935a cfg2cmd: sort PCI bridges when adding them for stabillity
In general it matters where a command line options is positioned
inside a QEMU command, so we want to actually also check the order in
the cfg2cmd test, to do so we need to avoid false positives like this
added.

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2019-10-09 07:51:13 +02:00
Aaron Lauterer
4d316a63c7 cfg2cmd: fix serial-bus for spice foldersharing
Thanks to Gilberto Nunes for finding a bug where the VM would not start
with foldersharing enabled and the qemu agent option disabled [0].

The cause was that the device org.spice-space.webdav.0 would not find a
virtio-serial-bus in this situation.

Since we always create a virtio-serial-bus for the spice vdagent it
seems sensible to use that also for the foldersharing device by moving
it in front of the other spice devices.

[0]: https://pve.proxmox.com/pipermail/pve-devel/2019-October/039441.html

Signed-off-by: Aaron Lauterer <a.lauterer@proxmox.com>
2019-10-08 18:15:00 +02:00
Alexandre Derumier
faf80f2566 qemu 4.0 : add Cascadelake-Server && KnightsMill cpu models
Signed-off-by: Alexandre Derumier <aderumier@odiso.com>
2019-09-30 16:44:51 +02:00