As noticed by one of the few users of routel script, it ends up in an
infinite loop when they pull out the cable from the NIC used for some
route. This is caused by its parser expecting the line of "ip route show"
output consists of "key value" pairs (except for the initial target range),
together with an old trap of Bourne style shells that "shift 2" does
nothing if there is only one argument left. Some keywords, e.g. "linkdown",
are not followed by a value.
Improve the parser to
(1) only set variables for keywords we care about
(2) recognize (currently) known keywords without value
This is still far from perfect (and certainly not future proof) but to
fully fix the script, one would probably have to rewrite the logic
completely (and I'm not sure it's worth the effort).
Signed-off-by: Michal Kubecek <mkubecek@suse.cz>
'ip vrf pids' is used to list processes bound to a vrf, but it only
shows the pid leaving a lot of work for the user. Add the command
name to the output. With this patch you get the more user friendly:
$ ip vrf pids mgmt
1121 ntpd
1418 gdm-session-wor
1488 gnome-session
1491 dbus-launch
1492 dbus-daemon
1565 sshd
...
Signed-off-by: David Ahern <dsa@cumulusnetworks.com>
These are basically stubs: The types which lacked their own help text
simply don't accept any options (yet). Still it might be a bit confusing
to users if they are presented with the generic 'ip link' help text
instead of something saying there are no type specific options.
Signed-off-by: Phil Sutter <phil@nwl.cc>
Take help function in iplink_bridge.c as an example and make other link
types' help functions similar:
* Use a single fprintf() call (if possible).
* Don't state a full command line, just "... type OPTIONS".
* Put every option in it's own line, align options by column.
* List mandatory options first.
link_veth.c is intentionally left untouched because it's 'peer' option
eats all kinds of generic link options and the help text points this out
without duplicating all the options there again.
Signed-off-by: Phil Sutter <phil@nwl.cc>
When neither group or remote is specified (or if they are specified with
the any address), nothing is sent to the kernel. In this case, the
kernel defaults to IPv4. This makes impossible to use IPv6 with
unspecified unicast remote ("bridge fdb add" will return
EAFNOTSUPPORT).
If the user specifies a preferred address family (eg, "ip -6 link add"),
then send either IFLA_VXLAN_GROUP or IFLA_VXLAN_GROUP6 to enforce the
use of the appropriate family.
Signed-off-by: Vincent Bernat <vincent@bernat.im>
MPLS multipath routes are missing a space between 'nexthop' and 'via':
$ ip -net ns1 -f mpls ro ls
100
nexthopvia inet 172.16.2.2 dev virt12
nexthopvia inet 172.16.3.2 dev br0
Add it.
Signed-off-by: David Ahern <dsa@cumulusnetworks.com>
Add support for new afstats subcommand. This uses the new
IFLA_STATS_AF_SPEC attribute of RTM_GETSTATS messages to show
per-device, AF-specific stats. At the moment the kernel only supports
MPLS AF stats, so that is all that's implemented here.
The print_num function is exposed from ipaddress.c to be used for
printing the new stats so that the human-readable option, if set, can
be respected.
Example of use:
$ ./ip/ip -f mpls link afstats dev eth1
3: eth1
mpls:
RX: bytes packets errors dropped noroute
9016 98 0 0 0
TX: bytes packets errors dropped
7232 113 0 0
Signed-off-by: Robert Shearman <rshearma@brocade.com>
Use the new helper functions rta_getattr_u* instead of direct
cast of RTA_DATA(). Where RTA_DATA() is a structure, then remove
the unnecessary cast since RTA_DATA() is void *
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
Add support for MPLS netconf to ip monitor and ip netconf commands.
Changes to header files not included as those are typically pulled
in my a header sync with the kernel.
Signed-off-by: David Ahern <dsa@cumulusnetworks.com>
This patch adds support to the bridge_slave link type for displaying
xstats by reusing the previously added bridge xstats callbacks.
Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
This patch adds support for a new xstats link subcommand which uses the
specified link type's new parse/print_ifla_xstats callbacks to display
extended statistics.
Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
Since cgroups are not namespace aware, the directory heirarchy used by
ip vrf should account for network namespaces. In this case, change the
path from CGRP/BASE/vrf/NAME to CGRP/BASE/NETNS/vrf/NAME where CGRP is
the cgroup2 mount path, BASE in any base heirarchy inherited before VRF
is applied and NAME is the VRF name.
The intent is as follows: a user logs into the box into some namespace
with a name known to iproute2. Some other policy may have put the
process into a BASE heirarchy. From there the user executes a task in
a VRF and in doing so the task heirarchy becomes CGRP/BASE/NETNS/vrf/NAME.
The namespace level is omitted for the default namespace.
Reported-by: Andy Lutomirski <luto@amacapital.net>
Signed-off-by: David Ahern <dsa@cumulusnetworks.com>
Move guts of netns_identify into a standalone function that returns
the netns name in a given buffer.
Signed-off-by: David Ahern <dsa@cumulusnetworks.com>
Add support for VRF in a pre-existing hierarchy. For example, if the
current process is running in CGRP/foo/bar, the 'ip vrf exec NAME CMD'
should run CMD in the cgroup CGRP/foo/bar/vrf/NAME.
When listing process ids in a VRF, search for the directory vrf/NAME
regardless of base path (foo/bar/vrf/NAME and vrf/NAME) are still
running against the same vrf NAME.
Reported-by: Andy Lutomirski <luto@amacapital.net>
Signed-off-by: David Ahern <dsa@cumulusnetworks.com>
This patch implements support for the IFLA_BRPORT_FLUSH attribute
in iproute2 so it can flush bridge slave's fdb dynamic entries.
Signed-off-by: Hangbin Liu <liuhangbin@gmail.com>
Reviewed-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
This patch implements support for the IFLA_BR_MCAST_MLD_VERSION
attribute in iproute2 so it can change the mcast mld version.
Reviewed-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: Hangbin Liu <liuhangbin@gmail.com>
This patch implements support for the IFLA_BR_MCAST_IGMP_VERSION
attribute in iproute2 so it can change the mcast igmp version.
Reviewed-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: Hangbin Liu <liuhangbin@gmail.com>
This patch implements support for the IFLA_BR_MCAST_STATS_ENABLED
attribute in iproute2 so it can enable/disable mcast stats accounting.
Signed-off-by: Hangbin Liu <liuhangbin@gmail.com>
Reviewed-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
This patch implements support for the IFLA_BR_VLAN_STATS_ENABLED
attribute in iproute2 so it can enable/disable vlan stats accounting.
Signed-off-by: Hangbin Liu <liuhangbin@gmail.com>
Reviewed-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
This patch implements support for the IFLA_BR_FDB_FLUSH attribute
in iproute2 so it can flush bridge fdb dynamic entries.
Reviewed-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: Hangbin Liu <liuhangbin@gmail.com>
This patch adds a new field that is printed in the end of the line which
denotes the real entry state. Before this patch an entry's IIF could
disappear and it would look like an unresolved one (iif = unresolved):
(3.0.16.1, 225.11.16.1) Iif: unresolved
with no way to really distinguish it from an unresolved entry.
After the patch if the dumped entry has RTNH_F_UNRESOLVED set we get:
(3.0.16.1, 225.11.16.1) Iif: unresolved State: unresolved
for unresolved entries and:
(0.0.0.0, 225.11.11.11) Iif: eth4 Oifs: eth3 State: resolved
for resolved entries after the OIF list. Note that "State:" has ':' in
it so it cannot be mistaken for an interface name.
And for the example above, we'd get:
(0.0.0.0, 225.11.11.11) Iif: unresolved State: resolved
Also when dumping all routes via ip route show table all,
it will show up as:
multicast 225.11.16.1/32 from 3.0.16.1/32 table default proto 17 unresolved
Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
To specify multiple nexthops in a route the user is expected to use the
"nexthop" keyword which ip route uses to create the RTA_MULTIPATH.
However, ip route always accepts multiple 'via' keywords where only the
last one is used in the route leading to confusion. For example, ip
accepts this syntax:
$ ip ro add vrf red 1.1.1.0/24 via 10.100.1.18 via 10.100.2.18
but the route entered inserted by the kernel is just the last gateway:
1.1.1.0/24 via 10.100.2.18 dev eth2
which is not the full request from the user. Detect the presense of
multiple 'via' and give the user a hint to add nexthop:
$ ip ro add vrf red 1.1.1.0/24 via 10.100.1.18 via 10.100.2.18
Error: argument "via" is wrong: use nexthop syntax to specify multiple via
Signed-off-by: David Ahern <dsa@cumulusnetworks.com>
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
Fix "Policy buffer overflow" when trying to use deleteall with many
policies installed.
Signed-off-by: Alexander Heinlein <alexander.heinlein@secunet.com>
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
Entries with long vhost names in /proc/net/igmp have no whitespace
between name and colon, so sscanf() adds it to vhost and
'ip maddr show iface' doesn't include inet result.
Signed-off-by: Petr Vorel <pvorel@suse.cz>
Show ipv6 tunnel keys on presence of GRE_KEY flag for tunnel types
other than GRE. Aligns ipv6 behaviour with ipv4.
Signed-off-by: dforster@brocade.com
Next up a non-root user gets various bpf related error messages:
$ ip vrf exec mgmt bash
Failed to load BPF prog: 'Operation not permitted'
Kernel compiled with CGROUP_BPF enabled?
Catch the EPERM error and do not show the kernel config option.
Signed-off-by: David Ahern <dsa@cumulusnetworks.com>
A vrf is local to a namespace. Drop any VRF association before trying
to exec a command in the new namespace.
Signed-off-by: David Ahern <dsa@cumulusnetworks.com>
Path in vrf_switch for "default" VRF is supposed to be MNT/vrf not
MNT/default. Also, default_vrf flag is redundant with ifindex. Remove
the flag in favor of ifindex != 0.
Signed-off-by: David Ahern <dsa@cumulusnetworks.com>
Split ipvrf_identify into arg processing and a function that does the
actual cgroup file parsing. The latter function is used in a follow
on patch.
In the process, convert the reading of the cgroups file to use fopen
and fgets just in case the file ever grows beyond 4k. Move printing
of any error message and the vrf name to the caller of the new
vrf_identify.
Signed-off-by: David Ahern <dsa@cumulusnetworks.com>
Move the hint about CGROUP_BPF enabled to prog_load failure since
it fails before the attach. Update the existing error message to
print to stderr.
Signed-off-by: David Ahern <dsa@cumulusnetworks.com>
'ip vrf' follows the user semnatics established by 'ip netns'.
The 'ip vrf' subcommand supports 3 usages:
1. Run a command against a given vrf:
ip vrf exec NAME CMD
Uses the recently committed cgroup/sock BPF option. vrf directory
is added to cgroup2 mount. Individual vrfs are created under it. BPF
filter attached to vrf/NAME cgroup2 to set sk_bound_dev_if to the VRF
device index. From there the current process (ip's pid) is addded to
the cgroups.proc file and the given command is exected. In doing so
all AF_INET/AF_INET6 (ipv4/ipv6) sockets are automatically bound to
the VRF domain.
The association is inherited parent to child allowing the command to
be a shell from which other commands are run relative to the VRF.
2. Show the VRF a process is bound to:
ip vrf id
This command essentially looks at /proc/pid/cgroup for a "::/vrf/"
entry with the VRF name following.
3. Show process ids bound to a VRF
ip vrf pids NAME
This command dumps the file MNT/vrf/NAME/cgroup.procs since that file
shows the process ids in the particular vrf cgroup.
Signed-off-by: David Ahern <dsa@cumulusnetworks.com>
iplink_vrf has 2 functions used to validate a user given device name is
a VRF device and to return the table id. If the user string is not a
device name ip commands with a vrf keyword show a confusing error
message: "RTNETLINK answers: No such device".
Add a variant of rtnl_talk that does not display the "RTNETLINK answers"
message and update iplink_vrf to use it.