The support bundle feature(tm) asks for some data
from zebra in the form of a command that has
never existed in FRR. Looks like some
cruft snuck in remove.
Signed-off-by: Donald Sharp <sharpd@cumulusnetworks.com>
There are situations where POLLERR will be returned. But
since we were not handling it. Thread processing effectively
is turned into an infinite loop, which is bad.
Modify the code so that if we receive a POLLERR we turn it
into a read event to be handled as an error from the handler
function.
This was discovered in pim:
Thread statistics for pimd:
Showing poll FD's for main
--------------------------
Count: 14/1024
0 fd: 9 events: 1 revents: 0 mroute_read
1 fd: 12 events: 1 revents: 0 vty_accept
2 fd: 13 events: 1 revents: 0 vtysh_accept
3 fd: 11 events: 1 revents: 0 zclient_read
4 fd: 15 events: 1 revents: 0 mroute_read
5 fd: 16 events: 1 revents: 0 mroute_read
6 fd: 17 events: 1 revents: 0 pim_sock_read
7 fd: 19 events: 1 revents: 0 pim_sock_read
8 fd: 21 events: 1 revents: 0 pim_igmp_read
9 fd: 22 events: 1 revents: 0 pim_sock_read
10 fd: 23 events: 1 revents: 0 pim_sock_read
11 fd: 20 events: 1 revents: 0 vtysh_read
12 fd: 18 events: 1 revents: 0 pim_sock_read
13 fd: 24 events: 0 revents: 0
strace was showing this line over and over and over:
poll([{fd=9, events=POLLIN}, {fd=12, events=POLLIN}, {fd=13, events=POLLIN}, {fd=11, events=POLLIN}, {fd=15, events=POLLIN}, {fd=16, events=POLLIN}, {fd=17, events=POLLIN}, {fd=19, events=POLLIN}, {fd=21, events=POLLIN}, {fd=22, events=POLLIN}, {fd=23, events=POLLIN}, {fd=20, events=POLLIN}, {fd=18, events=POLLIN}, {fd=6, events=POLLIN}], 14, 20) = 1 ([{fd=21, revents=POLLERR}])
Signed-off-by: Donald Sharp <sharpd@cumulusnetworks.com>
Somewhere along the way the indentation for comments got
all messed up. Let's make it follow our standards and
also look right too.
Signed-off-by: Donald Sharp <sharpd@cumulusnetworks.com>
* When failing a config transaction due to a VRID conflict, describe the
error in the provided space
* When validating, allow the NB userdata lookup for interface object to
soft fail; but when applying, assert if it does not exist
Signed-off-by: Quentin Young <qlyoung@nvidia.com>
We were querying the NB for an interface and expecting it to exist, but
we were doing this during a validation run when the interface hasn't yet
been created, resulting in an abort. Adjust validation checks to handle
this scenario.
Signed-off-by: Quentin Young <qlyoung@nvidia.com>
Changing properties on an autoconfigured VRRP instance results in its
pointer being stored as a userdata in the NB tree, leading to UAF when
autoconfigure deletes the instance and then later NB operations take
place using the now-stale pointer.
Ticket: CM-29850
Signed-off-by: Quentin Young <qlyoung@cumulusnetworks.com>
We were noticing registration time of the last nht time.
Let's just store the original time, although I am a bit
dubious about the usefulness of this.
Signed-off-by: Donald Sharp <sharpd@cumulusnetworks.com>
Give the FRR users some examples of gRPC usage in scripts to let them
start experimenting with the new configuration interface provided by
YANG/northbound.
Signed-off-by: Rafael Zalamena <rzalamena@opensourcerouting.org>
Suppose you have more than 2 addresses on a pim interface:
lo up default 10.255.0.1/32
10.255.0.101/32
10.255.0.254/32
A `show ip pim int lo` gives us this:
eva# show ip pim interface lo
Interface : lo
State : up
Address : 10.255.0.1 (primary)
10.255.0.101/32
When we go look at the code that pulls secondary addresses in
we are using a prefix_cmp to know if we know about a secondary already
but were expecting true values instead of -1/0/1 being returned.
Modify code so that pim sees all secondary addresses
Signed-off-by: Donald Sharp <sharpd@cumulusnetworks.com>
Router Information are contained in opaque LSAs and when such a LSA
is received a new SR node for the advertising router is created.
However, the RI related data is currently not set when such a SR node
already exists. This can happen when e.g. link and prefix information
arrive before the RI and therefore an SR node is created.
This is now fixed by setting the data everytime the RI is received,
independent of the SR node already existing or not.
Signed-off-by: GalaxyGorilla <sascha@netdef.org>
As part of PR 6758 vrf vni converted to transactional cli.
Handle a scenario where vrf is not created yet (inactive) and vni
is mapped to the inactive vrf.
Testing Done:
bharat(config-vrf)# do show vrf
vrf vrf1 id 11 table 1001
vrf vrf5 inactive (configured)
bharat(config)# vrf vrf5
bharat(config-vrf)# vni 5005
bharat(config-vrf)# do show vrf vni
VRF VNI VxLAN IF L3-SVI State Rmac
vrf5 5005 None None Down None
bharat(config-vrf)# no vni 5005
bharat(config-vrf)# do show vrf vni
VRF VNI VxLAN IF L3-SVI State Rmac
Signed-off-by: Chirag Shah <chirag@cumulusnetworks.com>