# Realtek RTS54 HUB
|
|
|
|
## Introduction
|
|
|
|
This plugin allows the user to update any supported hub and attached downstream
|
|
ICs using a custom HUB-based flashing protocol. It does not support any RTS54xx
|
|
device using the HID update protocol.
|
|
|
|
Other devices connected to the RTS54xx using I2C will be supported soon.
|
|
|
|
## Firmware Format
|
|
|
|
The daemon will decompress the cabinet archive and extract a firmware blob in
|
|
an unspecified binary file format.
|
|
|
|
This plugin supports the following protocol IDs:
|
|
|
|
* com.realtek.rts54
|
|
* com.realtek.rts54.i2c
|
|
|
|
## GUID Generation
|
|
|
|
These devices use the standard USB DeviceInstanceId values, e.g.
|
|
|
|
* `USB\VID_0BDA&PID_5423&REV_0001`
|
|
* `USB\VID_0BDA&PID_5423`
|
|
* `USB\VID_0BDA`
|
|
|
|
## Update Behavior
|
|
|
|
The firmware is deployed when the device is in normal runtime mode, and the
|
|
device will reset when the new firmware has been written.
|
|
|
|
## Vendor ID Security
|
|
|
|
The vendor ID is set from the USB vendor, in this instance set to `USB:0x0BDA`
|
|
|
|
## External Interface Access
|
|
|
|
This plugin requires read/write access to `/dev/bus/usb`.
|