title: Plugin: CCGX
|
||
---
|
||
|
||
## Introduction
|
||
|
||
This plugin can flash firmware on Infineon (previously Cypress) CCGx USB-C
|
||
controller family of devices used in docks.
|
||
|
||
## Supported Protocols
|
||
|
||
This plugin supports the following protocol IDs:
|
||
|
||
* `com.cypress.ccgx` (deprecated)
|
||
* `com.cypress.ccgx.dmc` (deprecated)
|
||
* `com.infineon.ccgx`
|
||
* `com.infineon.ccgx.dmc`
|
||
|
||
## Device Flash
|
||
|
||
There are four kinds of flash layout. Single image firmware is not currently
|
||
supported in this plugin.
|
||
|
||
### Symmetric Firmware
|
||
|
||
In symmetric firmware topology, FW1 and FW2 are both primary (main) firmware
|
||
with identical sizes and functionality. We can only update FW1 from FW2 or FW2
|
||
from FW1. This does mean we need to update just one time as booting from either
|
||
firmware slot gives a fully functional device.
|
||
|
||
After updating the "other" firmware we can just use `CY_PD_DEVICE_RESET_CMD_SIG`
|
||
to reboot into the new firmware, and no further action is required.
|
||
|
||
### Asymmetric Firmware
|
||
|
||
In asymmetric firmware topology, FW1 is backup and FW2 is primary (main)
|
||
firmware with different firmware sizes. The backup firmware may not support all
|
||
dock functionality.
|
||
|
||
To update primary, we thus need to update twice:
|
||
|
||
Case 1: FW2 is running
|
||
|
||
* Update FW1 -> Jump to backup FW `CY_PD_JUMP_TO_ALT_FW_CMD_SIG` -> reboot
|
||
* Update FW2 -> Reset device `CY_PD_DEVICE_RESET_CMD_SIG` -> reboot -> FW2
|
||
|
||
Case 2: FW1 is running (recovery case)
|
||
|
||
* Update FW2 -> Reset device `CY_PD_DEVICE_RESET_CMD_SIG` -> reboot -> FW2
|
||
|
||
The `CY_PD_JUMP_TO_ALT_FW_CMD_SIG` command is allowed only in asymmetric FW, but
|
||
`CY_PD_DEVICE_RESET_CMD_SIG` is allowed in both asymmetric FW and symmetric FW.
|
||
|
||
### DMC(Dock Management Controller) Composite Firmware
|
||
|
||
In composite firmware topology, a single firmware image contains metadata and
|
||
firmware images of multiple devices including DMC itself in a dock system.
|
||
|
||
### DMC Factory Mode
|
||
|
||
Dock Management Controller devices have a *composite version* that is used to
|
||
describe the dock hardware as a whole, rather than enumerating and updating
|
||
each sub-component separately.
|
||
When OEMs have not followed the IHV-approved factory assembly process, the
|
||
composite number is unset and fwupd would display `0.0.0.0` in the GUI and
|
||
on the command line.
|
||
|
||
In fwupd >= 1.8.11 we detect if the device is in *factory mode* and set the
|
||
version number to `0.0.0.1`.
|
||
When the device is in factory mode any valid upgrade will be allowed, which
|
||
means the user might be prompted to “update to” the same current version
|
||
installed on the dock.
|
||
For millions of devices this is both a waste of time, resources, and also
|
||
would inconvenience the user with an additional process for no reason.
|
||
|
||
For devices that have been shipped in factory mode, but would like to avoid
|
||
the update from `0.0.0.1` to the original version on the LVFS, can add a
|
||
quirk entry which matches the `devx` subcomponent *base version*.
|
||
In this example we match the parent VID, PID, the ComponentID and the `devx`
|
||
base firmware version, setting the parent composite version to `0.0.0.15`.
|
||
|
||
[USB\VID_2188&PID_0035&CID_05&VER_3.3.1.69]
|
||
CcgxDmcCompositeVersion = 15
|
||
|
||
All the `devx` subcomponent versions can be shown on the console using:
|
||
|
||
sudo fwupdtool –plugins ccgx get-devices –show-all –verbose
|
||
|
||
## Firmware Format
|
||
|
||
There are two kinds of firmware format.
|
||
|
||
### Cyacd firmware format
|
||
|
||
The daemon will decompress the cabinet archive and extract several firmware
|
||
blobs in cyacd file format. See <https://community.cypress.com/docs/DOC-10562>
|
||
for more details.
|
||
|
||
### DMC composite firmware format
|
||
|
||
The daemon will decompress the cabinet archive and extract several firmware
|
||
blobs in a combined image file format. See 4.4.1 Single Composite
|
||
(Combined) Dock Image at <https://www.cypress.com/file/387471/download>
|
||
for more details.
|
||
|
||
## GUID Generation
|
||
|
||
These devices use the standard USB DeviceInstanceId values, e.g.
|
||
|
||
* `USB\VID_1234&PID_5678`
|
||
|
||
Devices also have additional instance IDs which corresponds to the silicon ID,
|
||
application ID and device mode, e.g.
|
||
|
||
* `USB\VID_1234&PID_5678&SID_9ABC`
|
||
* `USB\VID_1234&PID_5678&SID_9ABC&APP_DEF1`
|
||
* `USB\VID_1234&PID_5678&SID_9ABC&APP_DEF1&MODE_FW2`
|
||
|
||
## Update Behavior
|
||
|
||
The device usually presents in runtime HID mode, but on detach re-enumerates
|
||
with with a DMC or HPI interface. On attach the device again re-enumerates
|
||
back to the runtime HID mode.
|
||
|
||
For this reason the `REPLUG_MATCH_GUID` internal device flag is used so that
|
||
the DMC/HPI and runtime modes are treated as the same device.
|
||
|
||
## Vendor ID Security
|
||
|
||
The vendor ID is set from the USB vendor, for example set to `USB:0x04B4`
|
||
|
||
## Quirk Use
|
||
|
||
This plugin uses the following plugin-specific quirks:
|
||
|
||
### CcgxDmcTriggerCode
|
||
|
||
DMC devices need a specified trigger code to request the device to update
|
||
the firmware and the trigger code depends on the devices.
|
||
|
||
0x0: Do not update
|
||
0x1: Update immediately
|
||
0x2: Update after port disconnected
|
||
|
||
Since: 1.8.0
|
||
|
||
### CcgxDmcCompositeVersion
|
||
|
||
Set the parent composite version, as a 32 bit integer.
|
||
|
||
Since: 1.8.11
|
||
|
||
## External Interface Access
|
||
|
||