// SPDX-License-Identifier: GPL-2.0-only OR MIT
/*
* Copyright (C) 2023-2024 Texas Instruments Incorporated - https://www.ti.com/
*/
#include <dt-bindings/thermal/thermal.h>
thermal_zones: thermal-zones {
main0_thermal: main0-thermal {
polling-delay-passive = <250>; /* milliSeconds */
polling-delay = <500>; /* milliSeconds */
thermal-sensors = <&wkup_vtm0 0>;
trips {
main0_alert: main0-alert {
temperature = <115000>;
hysteresis = <2000>;
type = "passive";
};
main0_crit: main0-crit {
temperature = <125000>; /* milliCelsius */
hysteresis = <2000>; /* milliCelsius */
type = "critical";
};
};
cooling-maps {
map0 {
trip = <&main0_alert>;
cooling-device =
<&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
<&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
<&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
<&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
};
};
};
main1_thermal: main1-thermal {
polling-delay-passive = <250>; /* milliSeconds */
polling-delay = <500>; /* milliSeconds */
thermal-sensors = <&wkup_vtm0 1>;
trips {
main1_alert: main1-alert {
temperature = <115000>;
hysteresis = <2000>;
type = "passive";
};
main1_crit: main1-crit {
temperature = <125000>; /* milliCelsius */
hysteresis = <2000>; /* milliCelsius */
type = "critical";
};
};
cooling-maps {
map0 {
trip = <&main1_alert>;
cooling-device =
<&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
<&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
<&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
<&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
};
};
};
main2_thermal: main2-thermal {
polling-delay-passive = <250>; /* milliSeconds */
polling-delay = <500>; /* milliSeconds */
thermal-sensors = <&wkup_vtm0 2>;
trips {
main2_alert: main2-alert {
temperature = <115000>;
hysteresis = <2000>;
type = "passive";
};
main2_crit: main2-crit {
temperature = <125000>; /* milliCelsius */
hysteresis = <2000>; /* milliCelsius */
type = "critical";
};
};
cooling-maps {
map0 {
trip = <&main2_alert>;
cooling-device =
<&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
<&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
<&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
<&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
};
};
};
};