Commit Graph

900 Commits

Author SHA1 Message Date
Wolfgang Bumiller
91b01bbbaa arm: use UART for serial0 instead of a separate device
Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-11-13 14:44:28 +01:00
Wolfgang Bumiller
6f0cb67588 only use vhost-net for native kvm machines
Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-11-13 14:44:28 +01:00
Wolfgang Bumiller
0f27a91d3d use cortex-a57 as cpu for arm emulation for now...
Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-11-13 14:44:28 +01:00
Wolfgang Bumiller
4fc262bd50 move cpu option creation into separate sub
Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-11-13 14:44:28 +01:00
Wolfgang Bumiller
6908fd9bf4 use qemu-system-aarch64 for arm machines
Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-11-13 14:44:28 +01:00
Wolfgang Bumiller
96ed3574d4 use AAVMF for arm
Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-11-13 14:44:28 +01:00
Wolfgang Bumiller
d731ecbefe add 'arch' vm configuration
Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-11-13 14:44:28 +01:00
Wolfgang Bumiller
646f2df43c fix and simplify kvm_version()
This was never actually used, but we want to use it as
alternative to checking /proc/cpuinfo for 'hvm' on ARM.

Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-11-13 14:44:28 +01:00
Dominik Csapak
8490283721 check for $vga->{type} instead of $vga
with commit 55655ebc32
we changed $vga to a parsed hash instead of a string
and forgot to check the property type in one place

this fixes an issue where a vm with a gpu passed through
with x-vga=on could not start

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2018-11-12 09:27:21 +01:00
David Limbeck
c9db224015 fix #1969: increase max unused disks
increase to 256, same as containers

Signed-off-by: David Limbeck <d.limbeck@proxmox.com>
2018-11-09 16:23:07 +01:00
Thomas Lamprecht
9c152e87f5 move nbd_stop up, it's not a completion helper
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-11-09 16:11:18 +01:00
Thomas Lamprecht
daadd5a4e7 followup for VGA memory: improve q35 comment
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-11-09 14:01:45 +01:00
Dominik Csapak
55655ebc32 fix #1952: make vga memory configurable
we change 'vga' to a property string and add a 'memory' property
with this, the user can better control the memory given to the virtual
gpu, this is especially useful for spice/qxl since high resolutions need
more memory

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2018-11-09 13:45:07 +01:00
Nick Chevsky
6c875f9f31 Add ssd property to IDE, SATA, and SCSI drives
When enabled, the `ssd` property exposes drives as SSDs (rather than
rotational hard disks) by setting QEMU's `rotation_rate` property [1,
2] on `ide-hd`, `scsi-block`, and `scsi-hd` devices. This is required
to enable support for TRIM and SSD-specific optimizations in certain
guest operating systems that are limited to emulated controller types
(IDE, AHCI, and non-VirtIO SCSI).

This change also unifies the diverging IDE and SATA code paths in
QemuServer::print_drivedevice_full(), which suffered from:
* Code duplication: The only differences between IDE and SATA were in
bus-unit specification and maximum device counts.
* Inconsistent implementation: The IDE code used the new `ide-hd`
and `ide-cd` device types, whereas SATA still relied on the deprecated
`ide-drive` [3, 4] (which doesn't support `rotation_rate`).
* Different feature sets: The IDE code exposed a `model` property that
the SATA code didn't, even though QEMU supports it for both.

[1] https://bugzilla.redhat.com/show_bug.cgi?id=1498042
[2] https://lists.gnu.org/archive/html/qemu-devel/2017-10/msg00698.html
[3] https://www.redhat.com/archives/libvir-list/2012-March/msg00684.html
[4] https://lists.gnu.org/archive/html/qemu-devel/2017-05/msg02024.html

Signed-off-by: Nick Chevsky <nchevsky@gmail.com>
2018-10-30 09:22:20 +01:00
Dominik Csapak
71bd73b534 add second qmp socket with qemu 2.12
we will use this for the qmeventd, but we have to limit this
to qemu 2.12, because we cannot add this during a live migration

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2018-10-18 12:23:48 +02:00
Wolfgang Bumiller
df648a6a7a lower hv_synic, hv_stimer requirement to qemu 2.12
Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-10-16 14:52:28 +02:00
Alexandre Derumier
29004a20ca qemu_img_convert : use "-l snapshot.name" instead -s for internal snapshot
qemu-img convert -s has been removed in qemu 3.0
https://git.qemu.org/?p=qemu.git;a=commit;h=46e8d272baa0608adcfdbd8bc1d2312bea06da40

we should use qemu-img convert -l snapshot.name=<snapname>,
introduced in qemu 2.0 in 2013
http://patchwork.ozlabs.org/patch/296457/
2018-10-08 13:16:12 +02:00
Dominik Csapak
64a320303f add virtio gpu to qemuserver options
and sort the list

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2018-09-28 09:59:05 +02:00
Wolfgang Bumiller
eba2b72199 use qemu's blockdev-snapshot functions
Instead of our own. The code is almost the same, but the
upstream implementation uses qemu's transactional system and
performs a drain() on the block device first. This seems to
help avoid some issues we run into with qcow2 files when
creating snapshots.

Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-09-24 11:12:34 +02:00
Thomas Lamprecht
babecffe00 restore vm: vmgenid: fixup regex capturing group reference
Reported-by: Dominik Csapak <d.csapak@proxmox.com>
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-09-19 14:16:02 +02:00
Thomas Lamprecht
f7ed64e7b9 schema: vmgenid: reword desscription, add verbose one and document default
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-09-19 14:01:05 +02:00
Thomas Lamprecht
1a0c2f032c restore vm: vmgenid: small code cleanup
do not use $1 do write out config, if code gets added this may easily
get overwritten, as vmgenid is a fixed key just hardcode it.

also move the comment to where it actually belongs

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-09-19 13:31:26 +02:00
Dominik Csapak
6ee499fff8 fix #1908: add vmgenid config/device
this adds a VM Generation ID device uses by Windows (Server) to determine
some specific actions that may have happened with the vm
such as rollback, restore, etc.

see:

https://docs.microsoft.com/en-us/windows/desktop/hyperv_v2/virtual-machine-generation-identifier

for details on how it works and when it should change

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2018-09-19 12:23:24 +02:00
Wolfgang Bumiller
dd84e5ec14 fix version check in qemu_machine_feature_enabled
This caused a few hiccups with qemu 3.0...

Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
Acked-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-09-18 09:37:32 +02:00
Dominik Csapak
c6737ef18b ensure correct machine type gets saved on snapshot
instead of overwriting the 'machine' config in the snapshot,
use its own 'runningmachine' config only for the snapshot

this way, we do not lose the machine type if it was
explicitely set during the snapshot, but deleted afterwards

we also have to adapt the tests for this

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2018-09-17 15:48:05 +02:00
Alexandre Derumier
ebb346d6fa qemu 3.0 : add hv_synic && hv_stimer hyperv enlightment
This fix cpu bug on last win10 updates
2018-09-17 13:40:28 +02:00
Alexandre Derumier
eabc189ee8 add ibpb, ssbd, virt-ssbd, amd-ssbd, amd-no-ssb, pdpe1gb cpu flags
> The following are important CPU features that should be used on
> Intel x86 hosts, when available in the host CPU. Some of them
> require explicit configuration to enable, as they are not included
> by default in some, or all, of the named CPU models listed above.
> In general all of these features are included if using “Host
> passthrough” or “Host model”.
>
> pcid: Recommended to mitigate the cost of the Meltdown
> (CVE-2017-5754) fix. Included by default in Haswell, Broadwell &
> Skylake Intel CPU models. Should be explicitly turned on for
> Westmere, SandyBridge, and IvyBridge Intel CPU models. Note that
> some desktop/mobile Westmere CPUs cannot support this feature.
>
> spec-ctrl: Required to enable the Spectre (CVE-2017-5753 and
> CVE-2017-5715) fix, in cases where retpolines are not sufficient.
> Included by default in Intel CPU models with -IBRS suffix. Must be
> explicitly turned on for Intel CPU models without -IBRS suffix.
> Requires the host CPU microcode to support this feature before it
> can be used for guest CPUs.
>
> ssbd: Required to enable the CVE-2018-3639 fix. Not included by
> default in any Intel CPU model. Must be explicitly turned on for
> all Intel CPU models. Requires the host CPU microcode to support
> this feature before it can be used for guest CPUs.
>
> pdpe1gbr: Recommended to allow guest OS to use 1GB size pages.Not
> included by default in any Intel CPU model. Should be explicitly
> turned on for all Intel CPU models. Note that not all CPU hardware
> will support this feature.
-- https://www.berrange.com/posts/2018/06/29/cpu-model-configuration-for-qemu-kvm-on-x86-hosts/
2018-08-28 11:19:10 +02:00
Stoiko Ivanov
9d66b39769 Make agent a property string, add fstrim_cloned_disks
Signed-off-by: Stoiko Ivanov <s.ivanov@proxmox.com>
2018-08-02 11:35:50 +02:00
Dietmar Maurer
b1a70cab3d vmstatus: define return propertries
We can use the same properties in vmlist and vmstatus.

Signed-off-by: Dietmar Maurer <dietmar@proxmox.com>
2018-08-01 12:58:21 +02:00
Alexandre Derumier
a2f1554b6e Fix #1717: delete snapshot when vm running and drive not attached
changelog v2:
 - remove hash
 - remove check if cdrom

if we try to delete a snapshot, and that is disk from the snapshot
is not attached anymore (unused), we can't delete the snapshot
with qemu snapshot delete command (for storage which use it (qcow2,rbd,...))

example:

...
unused0: rbd:vm-107-disk-3

[snap1]
...
scsi2: rbd:vm-107-disk-3,size=1G

-> die
 qmp command 'delete-drive-snapshot' failed - Device 'drive-scsi2' not found

If drive is not attached, we need to use the storage snapshot delete command
2018-07-19 10:42:03 +02:00
Dzmitry Kotsikau
a489dd9c81 Fix SPICE multi-monitor mode on q35
Signed-off-by: Dzmitry Kotsikau <dkotsikau@gmail.com>
2018-07-13 09:51:36 +02:00
Thomas Lamprecht
9224dceefe qm rescan: add dryrun option
tells an user what would get touched, so he has a chance to fix
unwanted things before changes are actually made.

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-07-11 09:35:45 +02:00
Thomas Lamprecht
53b81297c4 rescan update_disksize: be more verbose
Else an user has no idea what, or if something happened.

Gets printed to tty when using qm rescan or to tasklog for the case
where we do a rescan after restoring a backup.

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-07-11 09:35:43 +02:00
Thomas Lamprecht
b9a1a3aba5 rescan: comment that this is a temporarily workaround
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-07-05 08:46:11 +02:00
Alwin Antreich
4771526af1 Fix #1650: add content type filter to rescan
Unused disk(s) appeared after a rescan of storages. Especially shown
with ceph pools, where two storage entries are made, <storage>_ct and
<storage>_vm. The rescan method did include images from both storages.

This patch filters any storage not containing the content type 'images'.

Signed-off-by: Alwin Antreich <a.antreich@proxmox.com>
2018-07-05 08:35:06 +02:00
Wolfgang Bumiller
d04d6af1f2 use the new PVE::SystemD package
Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-06-15 11:50:23 +02:00
Dominik Csapak
c2786bedc6 use 'system_wakeup' to resume suspended vms
when a vm is suspended (e.g. autosuspend on windows)
we detect that it is not running, display the resume button,
but 'cont' does not wakeup the system from suspend

with this we can wake up suspended vms

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2018-06-13 12:46:01 +02:00
Thomas Lamprecht
a4938c7217 add nowarn to qga_check_running
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-05-30 09:01:11 +02:00
Dominik Csapak
f889aa0fbb fix #1780: change datacenter.conf to datacenter.cfg
Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2018-05-23 10:28:40 +02:00
Dominik Csapak
51153f86ce cleanup balloon after start call
the not definedness check is unecessary here, since it does not
do anything then, and to check balloon twice is also not necessary

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2018-05-22 13:23:29 +02:00
Dominik Csapak
75b51053cc fix logic of deleting balloon
Deleting the balloon config entry means resetting it to its
default. This means having a balloon device but not actually
doing any ballooning with it (iow. resetting the VM's
'balloon' value to its specified memory.).
Hotplugging a balloon device (coming from explicit '0' to
any other value (including deleting it)) is not possible.

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2018-05-22 13:20:16 +02:00
Dominik Csapak
82329cd55b note that auto-ballooning is done by pvestatd
so that one is not confused when seeing that the shares
parameter does nothing in qemu-server

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2018-05-22 13:20:11 +02:00
Wolfgang Bumiller
503308ed91 start: fork before entering scope
To avoid potential cleanup & post-start actions to cause
unwanted processes (such as gpg-agent) to be started as part
of the scope, as the enter_systemd_scope() function causes
the current process to enter the scope.

Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-05-08 08:40:24 +02:00
Dominik Csapak
f721624b8e collect device list for nested pci-bridges
when using q35 as machine type, there are nested pci-bridges,
but we only checked the first layer

this resulted in not being able to hotplug scsi devices,
because scsihw0 was deeper in the pci-bridge construct, we did not see
it and tried to add it (which fails of course)

this patch checks all bridges, regardless how deeply nested they are

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2018-04-13 14:44:22 +02:00
Dominik Csapak
3807f3e4ee fix #1697: only check machine type for pxe
it is not necessary to check the romfile of the running vm
for .pxe machine types, since the machine type itself is not
hot-pluggable

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2018-04-13 14:41:10 +02:00
Dominik Csapak
fd950b2385 readd nbd_stop
we accidentally moved nbd_stop to CloudInit.pm in
commit 0c9a7596f6

and removed it in
commit 3db6e4ab70

without realizing that live local storage migration still depends on it

readd it

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2018-04-13 14:39:06 +02:00
Thomas Lamprecht
a70e7e6caf disk: serial no must now be passed to device not drive
With QEMU 2.10 the serial parameter of the -drive command line option
was deprecated [1], so move the logic which adds this parameter now
to the -drive analogue -device CLI option.

Features marked deprecated will continue to work for two releases[2],
so we need to switch over before 2.12, AFAICT.

[1]: https://wiki.qemu.org/ChangeLog/2.10#Deprecated_options
[2]: https://qemu.weilnetz.de/doc/qemu-doc.html#Deprecated-features

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-04-09 11:03:02 +02:00
Fabian Grünbichler
d494009179 qemu-img convert: use cache=none for ZFS only
since this requires O_DIRECT support by the underlying storage, which
might not be available.

Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
2018-03-26 11:38:40 +02:00
Fabian Grünbichler
2715f95970 qemu-img convert: use cache=none
this fixes an issue with zvols, which require cache=none and eat up all
free memory as buffered pages otherwise

https://github.com/zfsonlinux/zfs/issues/7235

Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-03-23 14:57:49 +01:00
Thomas Lamprecht
102cf9d81e use pve-edk2-firmware for supporting OVMF
depend on new pve-edk2-firmware package and adapt the OVMF CODE/VARS
path accordingly

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-03-22 08:19:46 +01:00
Thomas Lamprecht
9444c6e42c fixup: remove unneeded if branch
$readfrom equals $archive here, and we're already in the branch with
the condition that both are not equal to '-'
2018-03-21 11:15:35 +01:00
Wolfgang Bumiller
7c536e11c4 restore: implement rate limiting
Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-03-21 11:15:35 +01:00
Thomas Lamprecht
b20df606a1 stop passing default '-k' QEMU option from datacenter.cfg
Modern noVNC does not needs this anymore, actually things may get
worse if it's used. E.g., when one sets 'de' and the VM locale is
'de' you may get a 'ĸ' (unicode kra) if you want to send an ampersand
character through pressing SHIFT + 6.

Qemus manual pages confirms that this is most times not needed
anymore:

 > -k language
 >    Use keyboard layout language (for example "fr" for
 >    French). This option is only needed where it is not
 >    easy to get raw PC keycodes (e.g. on Macs, with some
 >    X11 servers or with a VNC or curses display). You don't
 >    normally need to use it on PC/Linux or PC/Windows
 >    hosts.
 -- man kvm

An user can always set it per VM, wew simply remove the implict
default derived from the cluster wide datacenter.cfg

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-03-21 10:48:07 +01:00
Wolfgang Bumiller
345d263f6c cleanup: remove duplicate mac address assignment
The git history of this is not immediately obvious due to
the date of the cloud init patches, but the removal of this
line was basically reverted by them later at merge-time.

Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-03-21 10:33:39 +01:00
Thomas Lamprecht
6de521e984 remove legacy vm_monitor_command
We introduced our QMP socket with commit
c971c4f221 (29.05.2012)

Already tried to remove this with commit
7b7c6d1b5d (13.07.2012)

But reverted that to allow migration of VMs still using the old
montior to ones which already switched over to the new QMP one,
in commit dab36e1ee9 (17.08.2012)
see bug #242 for reference

This was all done  and released in PVE 2.2, as no migration through
nodes differing more than one major version is possible we can
finally remove this code for good.

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-03-14 11:18:56 +01:00
Herman van Rink
e4d4cda113 Move name argument to improve visibility in a process list
Signed-off-by: Herman van Rink <rink@initfour.nl>
2018-03-12 14:26:10 +01:00
Wolfgang Bumiller
3c23aa808c start: always stop an existing $vmid.scope
Checking for the cgroup directory is a kind of time-of-check
time-of-use race condition stop-mode backups seem to
occasionally run into on some systems.

Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-03-12 09:14:17 +01:00
Dietmar Maurer
1d1c4e1c1c cleanup cloud-init option descriptions 2018-03-07 10:53:41 +01:00
Dietmar Maurer
498cdc36dc document defaults for citype 2018-03-07 09:31:44 +01:00
Dietmar Maurer
d41121fdc4 new helper cloudinit_config_properties()
Only used to generate documentation.
2018-03-07 09:26:33 +01:00
Wolfgang Bumiller
e8ac21381e cloud-init: remove separate hostname config entry
Use the vm name and set hostname and fqdn in user data
again.

Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-03-07 09:15:42 +01:00
Wolfgang Bumiller
7b42f95142 cloud-init: add ciuser and cipassword config options
Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-03-07 09:11:32 +01:00
Wolfgang Bumiller
41cd94a01e cloud-init: nocloud image support
With configdrives we end up with the /etc/network/interfaces
file containing the interface names we use on the disk, ie.
eth0/eth1/..., which doesn't work on systems which do not
use this name.

With the 'nocloud' image type we can provide a
network-config in yaml which matches mac addresses. Ideally
we'd use version 2, but debian stretch ships with a too old
cloud-init for this, so for now we're writing version 1.

Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-03-07 09:11:31 +01:00
Wolfgang Bumiller
931432bd2d cloud-init: clone/move support
move: don't error out with "you can't move a cdrom"
clone: always full-clone cloud-init images
  They get completely replaced anyway at the next start, so
  there's no point in keeping them.

Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-03-07 09:11:31 +01:00
Wolfgang Bumiller
9ed7a77c6e cloud-init: hotplug support
*) always replace old cloudinit images
*) apply pending cloudinit changes when generating a new
image

For cloudinit we now always use vdisk_free before
vdisk_alloc in order to always replace old images, this
allows us to hotplug a new drive by setting it to
`none,media=cdrom` first (to eject the disk), then setting
it back to 'storage:cloudinit' to have a new image generated
after applying the currently pending changes.
2018-03-07 09:11:31 +01:00
Wolfgang Bumiller
2d9ddec5af cloud-init: don't add cloudinit isos as 'unused'
They're regenerated anyway as needed.
2018-03-07 09:11:31 +01:00
Wolfgang Bumiller
9c52f5edb6 cloud-init: delete cloudinit images as if they weren't cdroms 2018-03-07 09:11:31 +01:00
Alexandre Derumier
0c9a7596f6 implement cloudinit
Signed-off-by: Alexandre Derumier <aderumier@odiso.com>
Co-developed-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-03-07 09:11:31 +01:00
Wolfgang Bumiller
15cf76988d parse_vm_config: allow spaces in values
This time we can't avoid it: nameservers are listed with
separating spaces in LXC and we want to stay consistent and
use the same format in qemu.
2018-03-01 10:51:41 +01:00
Alexandre Derumier
b796ac7365 allow virtio-scsi + iothread controller hot-unplug 2018-02-22 10:50:37 +01:00
Wolfgang Bumiller
2a850ee870 CPU types: add EPYC and EPYC-IBPB
Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-02-21 09:51:01 +01:00
Thomas Lamprecht
1e5143de74 nbd mirror: no need applying full regex on volid string anymore
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-02-16 14:43:56 +01:00
Alexandre Derumier
87955688fd Fix #1664: nbd mirror : remove socat tunnel
socat tunnel for nbd mirror was introduce here
https://pve.proxmox.com/pipermail/pve-devel/2017-January/024777.html
to workaround when nbd client was hanging on non responding nbd server.

We have added a 30s timeout on socat tunnel, but when we migrate
multiple disks, it can break migration if for example first disk
is already finished and don't send any new datas in the tunnel.

The connect timeout bug has been fixed in qemu 2.9,
so we can remove the socat tunnel now.
2018-02-16 13:58:56 +01:00
Chris Hofstaedtler
ec82e3eee4 fix #1569: add shared flag to disks
With shared=1, (live) migration ignores the disk and assumes it is
present on all target nodes. This works similar to shared=1 on LXC
mountpoints.

Signed-off-by: Chris Hofstaedtler <chris.hofstaedtler@deduktiva.com>
Reviewed-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
Tested-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-02-15 15:19:29 +01:00
Wolfgang Bumiller
bfb04cfc01 correct 'snapshot' flag description
Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-02-08 13:41:27 +01:00
Dominik Csapak
5fc748614f append option to drive if the option is defined
if the value was '0', we did not append the option to the drive,
resulting in wrong command line if the qemu default of an option is not
'0'

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2018-02-08 13:29:06 +01:00
Dominik Csapak
8a2677081d fix #1662: use special case for 'snapshot' disk parameter
since qemu expects on|off (not 1|0),
we have to do it different

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2018-02-08 13:28:55 +01:00
Wolfgang Link
19a5dd551d Make the smbios UUID unique if --unique is used.
When we clone a VM we also make the smbios unique.
2018-02-05 14:38:41 +01:00
Dominik Csapak
8107b378c9 add serial:1 to vmstatus when config has a serial device configured
Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
Reviewed-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
Tested-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
Acked-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-01-30 16:36:38 +01:00
Fabian Grünbichler
049fc9ebe7 CPU flags: add spec-ctrl
to allow VMs to use IBRS/IBPB on systems with patched microcode

Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
2018-01-16 14:12:18 +01:00
Fabian Grünbichler
a446dbf46b CPU types: add missing types
Skylake-Server is the Xeon variant of Skylake

max is "all features supported by the accelerator in the current host"

Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
2018-01-16 14:10:57 +01:00
Fabian Grünbichler
9052cabab6 CPU types: add -IBRS variants
this have the 'spec-ctrl' flag by default to allow IBRS based Spectre
mitigation by the guest kernel.

Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
2018-01-16 14:10:57 +01:00
Alexandre Derumier
f38de678e4 increase start timeout when hugepages are enabled.
Hugepages can take some time to be allocated by qemu at start (60s for 120G of 1G hugepages).
This patch increase start timeout to 5min when hugepages are enabled.
2018-01-10 15:08:26 +01:00
Wolfgang Bumiller
39fd79e2ad add 'flags' property to cpu option
Currently this only allows specifying '+pcid' or '-pcid'
but might be extended in the future.

Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2018-01-09 15:42:53 +01:00
Wolfgang Bumiller
13bca7b4de fix efi disk format detection
Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
Fixes: 2bfbee039b ("include format for efidisk")
Reviewed-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
Tested-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2018-01-09 15:20:51 +01:00
Emmanuel Kasper
3618ee99aa Use default values from load_defaults() when none is specified in conf
This also fixes a bug where VMs with no memory defined in the config
where reported as using 0MB instead of 512.

Signed-off-by: Emmanuel Kasper <e.kasper@proxmox.com>
2017-12-15 13:05:59 +01:00
Dominik Csapak
c449137a04 do not add unused disk when already as unused on another storage
when having an unused disk on a storage for which there are multiple
definitions, we added it again on another storage when that storage
was alphabetically before the already existing one

this happens for example when using our automatically generated
ceph storages: 'pool_ct' and 'pool_vm' and having a vm with
an unused disk

with this patch, we also leave the unused disks in the hash

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2017-11-20 14:38:48 +01:00
Dominik Csapak
aea47dd6a0 fix #1471: change keyboard default to undef
this means that we do not include the '-k' parameter anymore by default
(which is deprecated by qemu)

with this, noVNC and spice always respect the guest keyboard
configuration and altgr keys work without problems

tested:
ubuntu with english intl and german with novnc and spice
windows 10 with english intl and german with novnc and spice
live migration

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2017-11-15 13:16:38 +01:00
Wolfgang Bumiller
6941ee4e1c fix typo
Signed-off-by: Wolfgang Bumiller <w.bumiller@proxmox.com>
2017-11-10 11:27:05 +01:00
Dominik Csapak
1a988fd2e8 check if ga runs before a fsfreeze-freeze/thaw
since the guest-fsfreeze-freeze command has a timeout of 1 hour,
we want to check if the guest-agent even runs before executing that,
or else we wait 1 hour and then continue

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
Reviewed-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2017-11-10 11:20:55 +01:00
Thomas Lamprecht
44c2a647ff update ostype documentation
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2017-11-07 08:47:15 +01:00
Dominik Csapak
2bfbee039b include format for efidisk
if the efidisk is in 'raw' format, qemu will prevent writes
on block zero if the format is not explicitely given

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2017-11-07 08:45:25 +01:00
Philip Abernethy
237239bf60 correct cpuunits range
'These options take an integer value and control the "cpu.shares"
control group attribute. The allowed range is 2 to 262144. Defaults to
1024.' – man 5 systemd.resource-control
2017-10-17 14:10:49 +02:00
Dominik Csapak
5e67a2d2c4 check if base volumes are unused before deleting a template
we only checked if a vm had in use base disks when deleting them,
at which point we do not stop to delete the vm even when a
disk deletion fails, which means we could successfully delete the config
and all not used (base) disks of a template, resulting in left over vm disks

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2017-10-13 10:18:34 +02:00
Emmanuel Kasper
ae2fcb3be6 Refactor defaut bootdisk and smbios1 uuid generation in own subs
This will allow code reuse for qm importovf
2017-09-25 13:31:55 +02:00
Fabian Grünbichler
8ddbcf8bd6 use foreach_drive in foreach_storage_used_by_vm
Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
2017-09-22 10:02:54 +02:00
Fabian Grünbichler
8cad5e9bd8 config: make vmstatestorage hotpluggable
since this is just an option for PVE, and does not concern the VM at all.

Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
2017-09-22 10:02:54 +02:00
Fabian Grünbichler
65a5ce88e6 rename foreach_writable_storage to foreach_storage_used_by_vm
Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
2017-09-22 10:02:54 +02:00
Fabian Grünbichler
253624c76f config: add vmstatestorage option
and permission checks

Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
2017-09-22 10:02:54 +02:00
Emmanuel Kasper
6cb0144ae3 do not overwrite global signal handlers
perls 'local' must be either used in front of each $SIG{...}
assignments or they must be put in a list, else it affects only the
first variable and the rest are *not* in local context.

In all cases the global signal handlers we overwrote were in cli programs or
forked workers, not in daemons.
2017-09-14 15:25:28 +02:00
Thomas Lamprecht
4dcce9ee3c ovmf: deprecate old legay ovmf image and refactor
this was only kept for PVE 4.X where the switch to the newer OVMF
image with actual working persisten EFIVARS was made.

We do not ship this old image in PVE 5.0 anymore so remove this
legacy code as it can never trigger anyhow.

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2017-09-11 10:04:46 +02:00
Thomas Lamprecht
3e1f112286 create_disks: refactor out and improve efidisk creation
factor out code in a new create_efidisk submethod, as else this code
is hardly readable as the efidisk0 case is a special case. Refer from
putting all this specialised handling directly to the much shorter
code for all other cases.

Also the disk was created with a specific format and then a format
detection on the newly created disk was done, which is pretty
useless, clear that up.

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2017-09-11 10:04:46 +02:00
Thomas Lamprecht
5b97ef2441 restore_vma_archive: do not overwrite global signal handlers
perls 'local' must be either used in front of each $SIG{...}
assignments or they must be put in a list, else it affects only the
first variable and the rest are *not* in local context.

This may cause weird behaviour where daemons seemingly do not get
terminating signals delivered correctly and thus may not shutdown
gracefully anymore.

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2017-09-07 10:39:34 +02:00
Philip Abernethy
bfcd9b7eac Fix #1125. Check for KVM support before starting VM
Moved the check to the beginning of the function.
VMs configured to use KVM won't start if KVM is not available.
VMs not configured to use KVM will start regardless.
2017-08-21 16:19:20 +02:00
Philip Abernethy
74c02ef7f8 Refactors $nokvm to $kvm
for improved readability and consistency with the option name.
2017-08-21 16:19:20 +02:00
Philip Abernethy
075e8249fa Refactor HyperV enlightenments
Fixes a typo in the function name and removes the $nokvm parameter, as it's only
used to immideately exit the function. Instead calling the function
conditionally.
2017-08-21 16:19:20 +02:00
Thomas Lamprecht
a2a5cd64ab use machine version in vga default type selection
If we get an VM machine older than 2.9 we use the old selection
expression for the VGA type. This allows to live migrate VMs to PVE
5.0 from beta 1 and PVE 4.4 again.

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2017-07-17 11:16:49 +02:00
Dominik Csapak
8aca16542e fix disk throttling syntax
the syntax was wrong, it was (e.g. for iops-write):

throttling.iops-write=-max100
instead of
throttling.iops-write-max=100

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2017-07-14 15:15:11 +02:00
Wolfgang Bumiller
85909c04c4 don't use cirrus by default for sane OS'
(It can stay for $winversion < 6 because then you probably
don't have drivers for anything else.)

this is long overdue
2017-06-28 12:07:16 +02:00
Dietmar Maurer
39019f75c7 PVE::QemuServer::foreach_volid - record snapshot references
So that we can test if a volume is referenced in the main config, and/or
inside a snapshot config.
2017-06-13 09:02:06 +02:00
Dietmar Maurer
392f8b5dff PVE::QemuServer::foreach_volid - pass $attr hash to callback
That way we can pass more informations, i.e. the 'replicate' attribute.
2017-06-13 09:02:06 +02:00
Wolfgang Bumiller
5ee3847149 fix #1405: sort pci ids by functions
QemuServer::lspci() iterates over /sys/bus/pci/devices which
doesn't guarantee any order which means functions sometimes
ended up in the wrong order and it was never clear which
one would get the additional options such as x-vga passed
to them.
2017-06-09 12:34:18 +02:00
Emmanuel Kasper
44549149af Refactor the resolution of target disk format in own sub
This will allow use to reuse the code in ImportDisk.pm.
2017-06-01 11:05:35 +02:00
Wolfgang Bumiller
fb8e95a218 fix burst length parameter names and pass them to qemu
bps_max_length & friends were wrongly named and were only
passed to qemu when hot-applying changes. They can only
be passed via the command line with their new names. For
consistency let's rename them all, that way they're all in
one place.

Fixes #1195 (for real this time).
2017-05-31 08:10:27 +02:00
Wolfgang Bumiller
911524414e fix #1229: more explicit spice port allocation
We cannot look for ports on "any" wildcard address while
letting qemu bind to "localhost", this may lead to a qemu
process occupying ::1 while the next search successfully
finds the same port available for IPv4's '*' address.

Instead, we now lookup the IP of the desired family for
'localhost'. Note that while we could simply be hardcoding
::1 or 127.0.0.1, with this code we are protocol agnostic.
2017-05-31 08:07:34 +02:00
Dietmar Maurer
3ab7663a91 remove 'replicate' configuration - we will store that in another file 2017-05-31 07:53:57 +02:00
Fabian Grünbichler
df58868200 print_cpu_device: remove unused variable 2017-05-23 14:23:52 +02:00
Tobias Böhm
7032e08c85 Fix #1384: add missing decrement to calculation of socket-id
For calculation of "current_core" the input variable id is decremented.
For calculation of "current_socket" this decrement was missing resulting
in a wrong value when "cores" is set to 1.

Signed-off-by: Tobias Böhm <tb@robhost.de>
2017-05-23 14:21:55 +02:00
Dietmar Maurer
3aa44d3b57 move get_replicatable_volumes from QemuServer.pm to QemuConfig.pm 2017-05-06 17:13:31 +02:00
Dietmar Maurer
0342b45bee get_replicatable_volumes: replacemnet for PVE::ReplicationTools::get_syncable_guestdisks()
correctly scan for volumes inside snapshots.

This will also solve the cyclic package dependency propblem.
2017-05-06 15:11:46 +02:00
Dietmar Maurer
8557d01f75 rename drive 'replica' property to 'replicate' 2017-05-06 10:46:21 +02:00
Dietmar Maurer
2286cb8c23 use a single replicate property (format pve-replicate) 2017-05-06 10:35:08 +02:00
Wolfgang Bumiller
1849c59288 whitespace fixup 2017-04-28 10:14:26 +02:00
Wolfgang Link
9edac22f5f Insert new properties in the Qemu config for the PVE Replica.
This patch will include all necessary properties for the replication.
Also will it enable and disable a replication job
when appointed flags are set or deleted.
2017-04-28 10:11:33 +02:00
Alexandre Derumier
6e9d255038 add rerror for all drives
it was missing for scsi, and it's supported for all kind of drive

Signed-off-by: Alexandre Derumier <aderumier@odiso.com>
2017-04-28 10:02:38 +02:00
Fabian Grünbichler
b37ecfe6ae start: keep VM paused when migrating via unix socket
this (correctly!) errored out with Qemu 2.9 when live-migrating
local disks, because the NBD server blocks the VM from being
resumed. was probably missed when migrating via unix domains
was originally introduced..

Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
2017-04-21 11:43:29 +02:00
Wolfgang Bumiller
d1782ebad3 don't compare booleans
a) because perl isn't THAT bad of a language that you'd need
to do this and b) because JSON::XS version 2.90 "dropped"
this "feature"
2017-04-03 14:13:15 +02:00
Dominik Csapak
3db920fc13 add Skylake to CPU Models
Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2017-02-28 12:19:14 +01:00
Wolfgang Bumiller
7fe1b688b6 fix bad scsihw default value check
This was checking for scsihw being set in both branches
whereas lsi is also the default. Added the missing 'not'.

Fixes a bug where a VM with a disk with a scsi index >= 7
refused to start due to an invalid scsi id.

Reported-by: Friedrich Ramberger <f.ramberger@proxmox.com>
2017-02-13 14:10:00 +01:00
Wolfgang Bumiller
1e4fb053d3 skiplock standard option was moved to pve-common
this now need libpve-common-perl >= 4.0-92
2017-02-08 09:56:02 +01:00
Fabian Grünbichler
5ff2bb065a change TLS cipher suite to HIGH
Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
2017-01-31 13:38:20 +01:00
Fabian Grünbichler
8e3c33ab64 only use scsi-block with explicit opt-in
since it can cause I/O errors and data corruption in low
memory or highly fragmented memory situations since Qemu 2.7

use scsi-hd by default instead

Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
2017-01-25 09:18:46 +01:00
Dmitry Petuhov
7246e8f92f Set zero $size and continue if volume_resize() returns false
Needed for some storages with backing block devices to do oonlinr resize.

Signed-off-by: Dmitry Petuhov <mityapetuhov@gmail.com>
2017-01-16 09:14:32 +01:00
Wolfgang Bumiller
9009150b81 cleanup: drop superfluous condition in assignment
Its use later on already uses itself as condition.
2017-01-09 15:33:12 +01:00
Alexandre Derumier
456a6fec00 add romfile option to hostpci
Signed-off-by: Alexandre Derumier <aderumier@odiso.com>
2017-01-09 15:31:18 +01:00
Wolfgang Bumiller
bd2d5fe6ff cleanup: error messages 2017-01-05 10:03:16 +01:00
Wolfgang Bumiller
923aaa9e1a drive-mirror: bump timeout to 5s, add 30s inactivity timeout 2017-01-05 10:03:16 +01:00
Wolfgang Bumiller
ca5c27f065 drive-mirror: warn use POSIX::_exit on exec failure 2017-01-05 10:03:16 +01:00
Wolfgang Bumiller
3b4cf0f0fc cleanup: whitespaces & style 2017-01-05 10:03:10 +01:00
Alexandre Derumier
5619e74aed live clone_vm : suspend or freezefs before block-job-cancel
if qga is enabled, we try to freeze the fs before cancelling block job.
if not , we pause the vm.

Signed-off-by: Alexandre Derumier <aderumier@odiso.com>
2017-01-05 09:09:46 +01:00
Alexandre Derumier
35e4ab0498 add socat and unix socket for storage migration
This is a workaround for nbd infinite timeout connect

Signed-off-by: Alexandre Derumier <aderumier@odiso.com>
2017-01-05 09:09:46 +01:00
Alexandre Derumier
63a0937008 add qm nbdstop
we use it to stop remote nbd server

Signed-off-by: Alexandre Derumier <aderumier@odiso.com>
2017-01-05 09:09:46 +01:00
Alexandre Derumier
2189246c5c add targetstorage to vm_start
This will create a new drive for each local drive found,
and start the vm with this new drives.

if targetstorage == 1, we use same sid than original vm disk

a nbd server is started in qemu and expose local volumes to network port

Signed-off-by: Alexandre Derumier <aderumier@odiso.com>
2017-01-05 09:09:46 +01:00
Alexandre Derumier
5a34596743 qemu_drive_mirror : handle multiple jobs
we can use multiple drive_mirror in parralel.

block-job-complete can be skipped, if we want to add more mirror job later.

also add support for nbd uri to qemu_drive_mirror

Signed-off-by: Alexandre Derumier <aderumier@odiso.com>
2017-01-05 09:09:46 +01:00
Fabian Grünbichler
31b522478d destroy_vm: allow vdisk_free to fail
otherwise we end up with undeletable VM configs in case
vdisk_free fails (which could happen because of cluster-wide
lock contention, storage problems, ..).

Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
2016-12-22 12:40:09 +01:00
Dietmar Maurer
b017fbda29 avoid "No balloon device has been activated" warnings in vmstatus 2016-12-20 10:11:56 +01:00
Thomas Lamprecht
b7a5a2251b allow insecure migrations from older qemu-servers
When trying to migrate a VM from a node with qemu server <= 4.0-92 to
a node with qemu server >= 4.0-93 we failed as the remote qemu-server
got no explicit migration_type' from the older qemu server on the
source.

Check if migration_type is defined on a incoming migration start, if
not set it.

Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
2016-12-02 18:48:49 +01:00
Emmanuel Kasper
0cb9971ec2 Add entry for windows 10 and 2016 support
All special flags for Windows 8 and Windows 2012 (win8 type)
are kept the same , since we set flags based on checking  if
/^win(\d+)$/ is greater than 6 or 7
2016-11-29 09:08:42 +01:00
Alexandre Derumier
1ef7592f1e qemu_volume_snapshot_delete : fix krbd snapshot delete
like for snapshot, we need to check if krbd is enabled, to known
if we need to use qmp delete-drive-snapshot or storage command directly

Signed-off-by: Alexandre Derumier <aderumier@odiso.com>
2016-11-17 09:46:16 +01:00
Alexandre Derumier
ac08761682 qxlnum: use $winversion
Signed-off-by: Alexandre Derumier <aderumier@odiso.com>
2016-11-11 09:54:39 +01:00