mirror of
				https://git.proxmox.com/git/mirror_zfs
				synced 2025-11-04 05:22:48 +00:00 
			
		
		
		
	Add ability to generate disk names that contain both a slot number and a lun number in order to support multi-actuator SAS hard drives with multiple luns. Also add the ability to zero pad slot numbers to a desired digit length for easier sorting. Reviewed-by: Tony Hutter <hutter2@llnl.gov> Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov> Signed-off-by: Matthew Heller <matthew.f.heller@accre.vanderbilt.edu> Closes #16603
		
			
				
	
	
		
			258 lines
		
	
	
		
			6.9 KiB
		
	
	
	
		
			Groff
		
	
	
	
	
	
			
		
		
	
	
			258 lines
		
	
	
		
			6.9 KiB
		
	
	
	
		
			Groff
		
	
	
	
	
	
.\"
 | 
						|
.\" This file and its contents are supplied under the terms of the
 | 
						|
.\" Common Development and Distribution License ("CDDL"), version 1.0.
 | 
						|
.\" You may only use this file in accordance with the terms of version
 | 
						|
.\" 1.0 of the CDDL.
 | 
						|
.\"
 | 
						|
.\" A full copy of the text of the CDDL should have accompanied this
 | 
						|
.\" source.  A copy of the CDDL is also available via the Internet at
 | 
						|
.\" http://www.illumos.org/license/CDDL.
 | 
						|
.\"
 | 
						|
.Dd May 26, 2021
 | 
						|
.Dt VDEV_ID.CONF 5
 | 
						|
.Os
 | 
						|
.
 | 
						|
.Sh NAME
 | 
						|
.Nm vdev_id.conf
 | 
						|
.Nd configuration file for vdev_id(8)
 | 
						|
.Sh DESCRIPTION
 | 
						|
.Nm
 | 
						|
is the configuration file for
 | 
						|
.Xr vdev_id 8 .
 | 
						|
It controls the default behavior of
 | 
						|
.Xr vdev_id 8
 | 
						|
while it is mapping a disk device name to an alias.
 | 
						|
.Pp
 | 
						|
The
 | 
						|
.Nm
 | 
						|
file uses a simple format consisting of a keyword followed by one or
 | 
						|
more values on a single line.
 | 
						|
Any line not beginning with a recognized keyword is ignored.
 | 
						|
Comments may optionally begin with a hash character.
 | 
						|
.Pp
 | 
						|
The following keywords and values are used.
 | 
						|
.Bl -tag -width "-h"
 | 
						|
.It Sy alias Ar name Ar devlink
 | 
						|
Maps a device link in the
 | 
						|
.Pa /dev
 | 
						|
directory hierarchy to a new device name.
 | 
						|
The udev rule defining the device link must have run prior to
 | 
						|
.Xr vdev_id 8 .
 | 
						|
A defined alias takes precedence over a topology-derived name, but the
 | 
						|
two naming methods can otherwise coexist.
 | 
						|
For example, one might name drives in a JBOD with the
 | 
						|
.Sy sas_direct
 | 
						|
topology while naming an internal L2ARC device with an alias.
 | 
						|
.Pp
 | 
						|
.Ar name
 | 
						|
is the name of the link to the device that will by created under
 | 
						|
.Pa /dev/disk/by-vdev .
 | 
						|
.Pp
 | 
						|
.Ar devlink
 | 
						|
is the name of the device link that has already been
 | 
						|
defined by udev.
 | 
						|
This may be an absolute path or the base filename.
 | 
						|
.
 | 
						|
.It Sy channel [ Ns Ar pci_slot ] Ar port Ar name
 | 
						|
Maps a physical path to a channel name (typically representing a single
 | 
						|
disk enclosure).
 | 
						|
.
 | 
						|
.It Sy enclosure_symlinks Sy yes Ns | Ns Sy no
 | 
						|
Additionally create
 | 
						|
.Pa /dev/by-enclosure
 | 
						|
symlinks to the disk enclosure
 | 
						|
.Em sg
 | 
						|
devices using the naming scheme from
 | 
						|
.Pa vdev_id.conf .
 | 
						|
.Sy enclosure_symlinks
 | 
						|
is only allowed for
 | 
						|
.Sy sas_direct
 | 
						|
mode.
 | 
						|
.
 | 
						|
.It Sy enclosure_symlinks_prefix Ar prefix
 | 
						|
Specify the prefix for the enclosure symlinks in the form
 | 
						|
.Pa /dev/by-enclosure/ Ns Ao Ar prefix Ac Ns - Ns Ao Ar channel Ac Ns Aq Ar num
 | 
						|
.Pp
 | 
						|
Defaults to
 | 
						|
.Dq Em enc .
 | 
						|
.
 | 
						|
.It Sy slot Ar prefix Ar new Op Ar channel
 | 
						|
Maps a disk slot number as reported by the operating system to an
 | 
						|
alternative slot number.
 | 
						|
If the
 | 
						|
.Ar channel
 | 
						|
parameter is specified
 | 
						|
then the mapping is only applied to slots in the named channel,
 | 
						|
otherwise the mapping is applied to all channels.
 | 
						|
The first-specified
 | 
						|
.Ar slot
 | 
						|
rule that can match a slot takes precedence.
 | 
						|
Therefore a channel-specific mapping for a given slot should generally appear
 | 
						|
before a generic mapping for the same slot.
 | 
						|
In this way a custom mapping may be applied to a particular channel
 | 
						|
and a default mapping applied to the others.
 | 
						|
.
 | 
						|
.It Sy zpad_slot Ar digits
 | 
						|
Pad slot numbers with zeros to make them
 | 
						|
.Ar digits
 | 
						|
long, which can help to make disk names a consistent length and easier to sort.
 | 
						|
.
 | 
						|
.It Sy multipath Sy yes Ns | Ns Sy no
 | 
						|
Specifies whether
 | 
						|
.Xr vdev_id 8
 | 
						|
will handle only dm-multipath devices.
 | 
						|
If set to
 | 
						|
.Sy yes
 | 
						|
then
 | 
						|
.Xr vdev_id 8
 | 
						|
will examine the first running component disk of a dm-multipath
 | 
						|
device as provided by the driver command to determine the physical path.
 | 
						|
.
 | 
						|
.It Sy topology Sy sas_direct Ns | Ns Sy sas_switch Ns | Ns Sy scsi
 | 
						|
Identifies a physical topology that governs how physical paths are
 | 
						|
mapped to channels:
 | 
						|
.Bl -tag -compact -width "sas_direct and scsi"
 | 
						|
.It Sy sas_direct No and Sy scsi
 | 
						|
channels are uniquely identified by a PCI slot and HBA port number
 | 
						|
.It Sy sas_switch
 | 
						|
channels are uniquely identified by a SAS switch port number
 | 
						|
.El
 | 
						|
.
 | 
						|
.It Sy phys_per_port Ar num
 | 
						|
Specifies the number of PHY devices associated with a SAS HBA port or SAS
 | 
						|
switch port.
 | 
						|
.Xr vdev_id 8
 | 
						|
internally uses this value to determine which HBA or switch port a
 | 
						|
device is connected to.
 | 
						|
The default is
 | 
						|
.Sy 4 .
 | 
						|
.
 | 
						|
.It Sy slot Sy bay Ns | Ns Sy phy Ns | Ns Sy port Ns | Ns Sy id Ns | Ns Sy lun Ns | Ns Sy bay_lun Ns | Ns Sy ses
 | 
						|
Specifies from which element of a SAS identifier the slot number is
 | 
						|
taken.
 | 
						|
The default is
 | 
						|
.Sy bay :
 | 
						|
.Bl -tag -compact -width "port"
 | 
						|
.It Sy bay
 | 
						|
read the slot number from the bay identifier.
 | 
						|
.It Sy phy
 | 
						|
read the slot number from the phy identifier.
 | 
						|
.It Sy port
 | 
						|
use the SAS port as the slot number.
 | 
						|
.It Sy id
 | 
						|
use the scsi id as the slot number.
 | 
						|
.It Sy lun
 | 
						|
use the scsi lun as the slot number.
 | 
						|
.It Sy bay_lun
 | 
						|
read the slot number from the bay identifier and append the lun number.
 | 
						|
Useful for multi-lun multi-actuator hard drives.
 | 
						|
.It Sy ses
 | 
						|
use the SCSI Enclosure Services (SES) enclosure device slot number,
 | 
						|
as reported by
 | 
						|
.Xr sg_ses 8 .
 | 
						|
Intended for use only on systems where
 | 
						|
.Sy bay
 | 
						|
is unsupported,
 | 
						|
noting that
 | 
						|
.Sy port
 | 
						|
and
 | 
						|
.Sy id
 | 
						|
may be unstable across disk replacement.
 | 
						|
.El
 | 
						|
.El
 | 
						|
.
 | 
						|
.Sh FILES
 | 
						|
.Bl -tag -width "-v v"
 | 
						|
.It Pa /etc/zfs/vdev_id.conf
 | 
						|
The configuration file for
 | 
						|
.Xr vdev_id 8 .
 | 
						|
.El
 | 
						|
.
 | 
						|
.Sh EXAMPLES
 | 
						|
A non-multipath configuration with direct-attached SAS enclosures and an
 | 
						|
arbitrary slot re-mapping:
 | 
						|
.Bd -literal -compact -offset Ds
 | 
						|
multipath     no
 | 
						|
topology      sas_direct
 | 
						|
phys_per_port 4
 | 
						|
slot          bay
 | 
						|
 | 
						|
#       PCI_SLOT HBA PORT  CHANNEL NAME
 | 
						|
channel 85:00.0  1         A
 | 
						|
channel 85:00.0  0         B
 | 
						|
channel 86:00.0  1         C
 | 
						|
channel 86:00.0  0         D
 | 
						|
 | 
						|
# Custom mapping for Channel A
 | 
						|
 | 
						|
#    Linux      Mapped
 | 
						|
#    Slot       Slot      Channel
 | 
						|
slot 1          7         A
 | 
						|
slot 2          10        A
 | 
						|
slot 3          3         A
 | 
						|
slot 4          6         A
 | 
						|
 | 
						|
# Default mapping for B, C, and D
 | 
						|
 | 
						|
slot 1          4
 | 
						|
slot 2          2
 | 
						|
slot 3          1
 | 
						|
slot 4          3
 | 
						|
.Ed
 | 
						|
.Pp
 | 
						|
A SAS-switch topology.
 | 
						|
Note, that the
 | 
						|
.Ar channel
 | 
						|
keyword takes only two arguments in this example:
 | 
						|
.Bd -literal -compact -offset Ds
 | 
						|
topology      sas_switch
 | 
						|
 | 
						|
#       SWITCH PORT  CHANNEL NAME
 | 
						|
channel 1            A
 | 
						|
channel 2            B
 | 
						|
channel 3            C
 | 
						|
channel 4            D
 | 
						|
.Ed
 | 
						|
.Pp
 | 
						|
A multipath configuration.
 | 
						|
Note that channel names have multiple definitions - one per physical path:
 | 
						|
.Bd -literal -compact -offset Ds
 | 
						|
multipath yes
 | 
						|
 | 
						|
#       PCI_SLOT HBA PORT  CHANNEL NAME
 | 
						|
channel 85:00.0  1         A
 | 
						|
channel 85:00.0  0         B
 | 
						|
channel 86:00.0  1         A
 | 
						|
channel 86:00.0  0         B
 | 
						|
.Ed
 | 
						|
.Pp
 | 
						|
A configuration with enclosure_symlinks enabled:
 | 
						|
.Bd -literal -compact -offset Ds
 | 
						|
multipath yes
 | 
						|
enclosure_symlinks yes
 | 
						|
 | 
						|
#          PCI_ID      HBA PORT     CHANNEL NAME
 | 
						|
channel    05:00.0     1            U
 | 
						|
channel    05:00.0     0            L
 | 
						|
channel    06:00.0     1            U
 | 
						|
channel    06:00.0     0            L
 | 
						|
.Ed
 | 
						|
In addition to the disks symlinks, this configuration will create:
 | 
						|
.Bd -literal -compact -offset Ds
 | 
						|
/dev/by-enclosure/enc-L0
 | 
						|
/dev/by-enclosure/enc-L1
 | 
						|
/dev/by-enclosure/enc-U0
 | 
						|
/dev/by-enclosure/enc-U1
 | 
						|
.Ed
 | 
						|
.Pp
 | 
						|
A configuration using device link aliases:
 | 
						|
.Bd -literal -compact -offset Ds
 | 
						|
#     by-vdev
 | 
						|
#     name     fully qualified or base name of device link
 | 
						|
alias d1       /dev/disk/by-id/wwn-0x5000c5002de3b9ca
 | 
						|
alias d2       wwn-0x5000c5002def789e
 | 
						|
.Ed
 | 
						|
.
 | 
						|
.Sh SEE ALSO
 | 
						|