Clang static analysis reports this problem
scd4x.c:474:10: warning: The left operand of '==' is a
garbage value
if (val == 0xff) {
~~~ ^
val is only set from a successful call to scd4x_write_and_fetch()
So check it's return.
Fixes: 49d22b695c ("drivers: iio: chemical: Add support for Sensirion SCD4x CO2 sensor")
Signed-off-by: Tom Rix <trix@redhat.com>
Link: https://lore.kernel.org/r/20220301025223.223223-1-trix@redhat.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
sysfs_emit() is preferred over raw s*printf() for sysfs attributes since it
knows about the sysfs buffer specifics and has some built-in checks for
size and alignment.
Use sysfs_emit() to format the custom `calibration_auto_enable` device
attribute of the scd4x driver.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Link: https://lore.kernel.org/r/20211216185217.1054495-13-lars@metafoo.de
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This patch adds a scale for the co2 concentration reading. The reading is
expressed in percent after applying the scale to the raw value.
Signed-off-by: Roan van Dijk <roan@protonic.nl>
Link: https://lore.kernel.org/r/20211021140018.3051213-1-roan@protonic.nl
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This is a driver for the SCD4x CO2 sensor from Sensirion. The sensor is
able to measure CO2 concentration, temperature and relative humdity.
The sensor uses a photoacoustic principle for measuring CO2 concentration.
An I2C interface is supported by this driver in order to communicate with
the sensor.
Signed-off-by: Roan van Dijk <roan@protonic.nl>
Link: https://lore.kernel.org/r/20211008101706.755942-4-roan@protonic.nl
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>