Topology Used:
=============
Cisco---FRR4----FRR2
Initially PIM nbr is down between FRR4----FRR2 from FRR2 side
Cisco is sending BSR packet to FRR4.
Problem Statement:
=================
No shutdown the PIM neighbor on FRR2 towards FRR4.
FRR2, receives BSR packet immediately as the new neighbor
comes up. This BSR packet is having no-forward bit set.
FRR2 is not able to process the BSR packet, and drop the
BSR packet.
Root Cause:
==========
When PIMD comes up, we start BSM timer for 60 seconds.
Here, the value accept_nofwd_bsm is setting to false.
FRR2, when receives no-forward BSR packet, it is getting
accept_nofwd_bsm value as false.
So, it drops, the no-forward BSM packet.
Fix:
===
Set accept_nofwd_bsm as false after first BSM packet received.
Signed-off-by: Sarita Patra <saritap@vmware.com>
update_type1_routes_for_evi() is called from
L3VNI/L2VNI up event, if ESI is not UP then
do not advertise EAD-ES Type-1 route.
Just like from multiple places EAD-ES route
origination checks for its oper status.
Ticket:#3413454
Issue:3413454
Signed-off-by: Trey Aspelund <taspelund@nvidia.com>
Signed-off-by: Chirag Shah <chirag@nvidia.com>
Alpine Linux has LUA_LIB with a broken path, let's use pkg-config to grab
the LUA_LIBS properly.
checking for library containing lua_load... no
configure: error: Lua 5.3 libraries are required to build with Lua support. No other version is supported.
Signed-off-by: Donatas Abraitis <donatas@opensourcerouting.org>
The date for removing some deprecated json attributes from
'show neighbor' has arrived, so remove the attrs (and the
CPP_NOTICE block).
Signed-off-by: Mark Stapp <mjs@labn.net>
When passing a prefix into a function let's pass by address instead
of pass by value. Let's save our stack space.
Signed-off-by: Donald Sharp <sharpd@nvidia.com>
When cleaning `ripd`, it should free `ctx->name` of `struct if_rmap_ctx`,
not `ctx` itself. Otherwise, it will lead to memory leak.
Signed-off-by: anlan_cs <vic.lan@pica8.com>
All other parsing functions done from bgp_nlri_parse() assume
no attributes == an implicit withdrawal. Let's move
bgp_nlri_parse_flowspec() into the same alignment.
Reported-by: Matteo Memelli <mmemelli@amazon.it>
Signed-off-by: Donald Sharp <sharpd@nvidia.com>
FRR's standards state that function declarations should
have actual variable names for parameters passed in.
Let's make this so for bgp_packet.h
Signed-off-by: Donald Sharp <sharpd@nvidia.com>
"show evpn json" returns nothing when evpn is disabled.
Code has been fixed to return {} when evpn is disabled or no entry
available.
Before Fix:-
```
cumulus@r2:mgmt:~$ sudo vtysh -c "show evpn json"
cumulus@r2:mgmt:~$
```
After Fix:-
```
cumulus@r1:mgmt:~$ sudo vtysh -c "show evpn json"
{
}
cumulus@r1:mgmt:~$
```
Ticket:#3417955
Issue:3417955
Testing: UT done
Signed-off-by: Chirag Shah <chirag@nvidia.com>
Signed-off-by: Sindhu Parvathi Gopinathan <sgopinathan@nvidia.com>
During shutdown, the main pthread stops the dplane pthread
before exiting. Don't try to clean up any events scheduled
to the dplane pthread at that point - just let the thread
exit and clean up.
Signed-off-by: Mark Stapp <mjs@labn.net>
If log-pdu-drops is configured, create an INFO log that displays the PDU type and drop counts when a PDU drop is detected.
Example logs:
2023/03/30 23:54:59.749 ISIS: [VAS9N-1JNNR] PDU drop detected of type: P2P IIH. 1 Total Drops; 0 L1 IIH drops; 0 L2 IIH drops; 1 P2P IIH drops; 0 L1 LSP drops; 0 L2 LSP drops; 0 FS LSP drops; 0 L1 CSNP drops; 0 L2 CSNP drops; 0 L1 PSNP drops; 0 L2 PSNP drops.
2023/03/30 23:54:59.848 ISIS: [VAS9N-1JNNR] PDU drop detected of type: P2P IIH. 2 Total Drops; 0 L1 IIH drops; 0 L2 IIH drops; 2 P2P IIH drops; 0 L1 LSP drops; 0 L2 LSP drops; 0 FS LSP drops; 0 L1 CSNP drops; 0 L2 CSNP drops; 0 L1 PSNP drops; 0 L2 PSNP drops.
Code changes:
Add a new PDU counter function that increments the drop counter and runs the logging functionality if log-pdu-drops is configured.
Signed-off-by: Isabella de Leon <ideleon@microsoft.com>
New config functionality:
r1# conf
r1(config)# router isis 1
r1(config-router)# log-
log-adjacency-changes Log changes in adjacency state
log-pdu-drops Log any dropped PDUs
r1(config-router)# log-pdu-drops
r1(config-router)# end
Signed-off-by: Isabella de Leon <ideleon@microsoft.com>