When clagd is stopped on secondary device,
all vxlan interfaces (vnis) are kept in protodown state.
FRR treats protodown vxlan interfaces (vnis) as interface down
and sends vni delete to bgpd.
In the event of clagd down, SVIs are flapping as underlying
bridge is going through churn.
When FRR receives SVI up notification do not trigger event to bgpd
if vnis are operationaly down.
Ticket:#2600210 CM-22929
Reviewed By:CCR-11544
Testing Done:
Performed CLAG stop/start on secondary device, all vxlan devices
remained in protodown along with this validated the vnis are cleaned up
and added back in bgpd.
Signed-off-by: Chirag Shah <chirag@nvidia.com>
When creating a large number of vrf's we are creating a fairly
large number of hash tables per vrf. Reduce memory usage on
startup as well as let us identify the table these things come
from.
Signed-off-by: Donald Sharp <sharpd@nvidia.com>
This is always a 16 bit unsigned value.
- signed int is the wrong type to use
- encoding a signed int as a uint32 is bad practice
- decoding a signed int encoded as a uint32 into a uint16 is bad
practice
Signed-off-by: Quentin Young <qlyoung@nvidia.com>
EVPN nexthops are installed as remote neighs by zebra. This was earlier
done only via VRF IPvX uni routes imported from EVPN routes.
With EVPN-MH these VRF routes now reference a L3NHG which is setup based
on the EAD and doesn't include the RMAC. To workaround that BGP now
consolidates and maintains EVPN nexthops which are then sent to zebra.
zebra sets up these nexthops as L3-VNI nh entries using a dummy type-1
route as reference.
Ticket: CM-31398
Signed-off-by: Anuradha Karuppiah <anuradhak@cumulusnetworks.com>
This one also needed a bit of shuffling around, but MTYPE_RE is the only
one left used across file boundaries now.
Signed-off-by: David Lamparter <equinox@diac24.net>
When an ES-bond comes out of bypass FRR needs to flush the local MACs learnt
while the bond was in bypass. To do that efficiently local MACs are linked
to the dest-access port. This only happens if the access-port is in
LACP-bypass or if it is non-ES.
Signed-off-by: Anuradha Karuppiah <anuradhak@cumulusnetworks.com>
Feature overview:
=================
A 802.3ad bond can be setup to allow lacp-bypass. This is done to enable
servers to pxe boot without a LACP license i.e. allows the bond to go oper
up (with a single link) without LACP converging.
If an ES-bond is oper-up in an "LACP-bypass" state MH treats it as a non-ES
bond. This involves the following special handling -
1. If the bond is in a bypass-state the associated ES is placed in a
bypass state.
2. If an ES is in a bypass state -
a. DF election is disabled (i.e. assumed DF)
b. SPH filter is not installed.
3. MACs learnt via the host bond are advertised with a zero ESI.
When the ES moves out of "bypass" the MACs are moved from a zero-ESI to
the correct non-zero id. This is treated as a local station move.
Implementation:
===============
When (a) an ES is detached from a hostbond or (b) an ES-bond goes into
LACP bypass zebra deletes all the local macs (with that ES as destination)
in the kernel and its local db. BGP re-sends any imported MAC-IP routes
that may exist with this ES destination as remote routes i.e. zebra can
end up programming a MAC that was perviously local as remote pointing
to a VTEP-ECMP group.
When an ES is attached to a hostbond or an ES-bond goes
LACP-up (out of bypss) zebra again deletes all the local macs in the
kernel and its local db. At this point BGP resends any imported MAC-IP
routes that may exist with this ES destination as sync routes i.e.
zebra can end up programming a MAC that was perviously remote
as local pointing to an access port.
Signed-off-by: Anuradha Karuppiah <anuradhak@cumulusnetworks.com>
Added support for advertising SVI MAC if EVPN-MH is enabled.
In the case of EVPN MH arp replies from an attached server can be sent to
the ES-peer. To prevent flooding of the reply the SVI MAC needs to be
advertised by default.
Note:
advertise-svi-ip could have been used as an alternate way to advertise
SVI MAC. However that config cannot be turned on if SVI IPs are
re-used (which is done to avoid wasting IP addresses in a subnet).
Signed-off-by: Anuradha Karuppiah <anuradhak@cumulusnetworks.com>
SVI IP is being advertised unconditionally i.e. even if disabled (and
that is the default config). This can be problematic when the SVI address
is re-used across racks.
Added the user config condition in all the relevant places where the
SVI advertisement is triggered.
Signed-off-by: Anuradha Karuppiah <anuradhak@cumulusnetworks.com>
Neither tabs nor newlines are acceptable in syslog messages. They also
break line-based parsing of file logs.
Signed-off-by: David Lamparter <equinox@diac24.net>
the old VXLAN function for local MAC deletion was still in
existence and being called from the VXLAN code whilst the new
generic function was not being called at all. Resolve this so
the generic function matches the old function and is called
exclusively.
Signed-off-by: Pat Ruddy <pat@voltanet.io>
If a netlink/dp notification is rxed for a neigh without the peer-sync
flag FRR re-installs the entry with the right flags. This change is
needed to handle cases where the dataplane and FRR may fall out of
sync because of neigh learning on the network ports (i.e. via
the VxLAN).
Ticket: CM-30693
The problem was found during VM mobility "torture" tests where 100s
of extended VM moves were done.
Signed-off-by: Anuradha Karuppiah <anuradhak@cumulusnetworks.com>
After removal of L3VNI config, the VNI should become an L2VNI if a VxLAN
interface is present for the VNI. This case is not handled in the code.
Changes:
1. After unconfiguring L3VNI, create an L2VNI if VxLAN interface is present
for the VNI.
2. Trigger an update to BGP.
3. Read MAC and ARP entries from kernel.
This PR fixes the issue only for route type-2, 3 and 5. This PR does not address
states regarding route type-1, 4 and multicast group for VxLAN interface.
Signed-off-by: Ameya Dharkar <adharkar@vmware.com>
When a local ES flaps there are two modes in which the local
MACs are failed over -
1. Fast failover - A backup NHG (ES-peer group) is programmed in the
dataplane per-access port. When a local ES flaps the MAC entries
are left unaltered i.e. pointing to the down access port. And the
dataplane redirects traffic destined to the oper-down access port
via the backup NHG.
2. Slow failover - This mode needs to be turned on to allow dataplanes
not capable of re-directing traffic. In this mode local MAC entries
on a down local ES are re-programmed to point to the ES-peers'
NHG. And vice-versa i.e. when the ES comes up the MAC entries
are re-programmed with the access port as dest.
Fast failover is on by default. Slow failover can be enabled via the
following config -
evpn mh redirect-off
Signed-off-by: Anuradha Karuppiah <anuradhak@cumulusnetworks.com>
There are two fixes in this commit -
1. Prevent implicit deletion of (*,G) entries during (S,G) cleanup.
This is done by creating a dummy reference on all (*,G) entries.
This is needed for a hash-walk based table cleanup.
2. Free up the SG hash table when the VRF is deleted.
Ticket: CM-30151
Signed-off-by: Anuradha Karuppiah <anuradhak@cumulusnetworks.com>
DAD is not supported currently with EVPN-MH so we turn it off internally
when the first ES config is detected.
PS: Note that when all local ESs are deleted DAD will stay off and
will need to be cleared via a daemon restart.
Signed-off-by: Anuradha Karuppiah <anuradhak@cumulusnetworks.com>
Local ethernet segments are held in a protodown or error-disabled state
if access to the VxLAN overlay is not ready -
1. When FRR comes up the local-ESs/access-port are kept protodown
for the startup-delay duration. During this time the underlay and
EVPN routes via it are expected to converge.
2. When all the uplinks/core-links attached to the underlay go down
the access-ports are similarly protodowned.
The ES-bond protodown state is propagated to each ES-bond member
and programmed in the dataplane/kernel (per-bond-member).
Configuring uplinks -
vtysh -c "conf t" vtysh -c "interface swp4" vtysh -c "evpn mh uplink"
Configuring startup delay -
vtysh -c "conf t" vtysh -c "evpn mh startup-delay 100"
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
EVPN protodown display -
========================
root@torm-11:mgmt:~# vtysh -c "show evpn"
L2 VNIs: 10
L3 VNIs: 3
Advertise gateway mac-ip: No
Advertise svi mac-ip: No
Duplicate address detection: Disable
Detection max-moves 5, time 180
EVPN MH:
mac-holdtime: 60s, neigh-holdtime: 60s
startup-delay: 180s, start-delay-timer: 00:01:14 <<<<<<<<<<<<
uplink-cfg-cnt: 4, uplink-active-cnt: 4
protodown: startup-delay <<<<<<<<<<<<<<<<<<<<<<<
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
ES-bond protodown display -
===========================
root@torm-11:mgmt:~# vtysh -c "show interface hostbond1"
Interface hostbond1 is up, line protocol is down
Link ups: 0 last: (never)
Link downs: 1 last: 2020/04/26 20:38:03.53
PTM status: disabled
vrf: default
OS Description: Local Node/s torm-11 and Ports swp5 <==> Remote Node/s hostd-11 and Ports swp1
index 58 metric 0 mtu 9152 speed 4294967295
flags: <UP,BROADCAST,MULTICAST>
Type: Ethernet
HWaddr: 00:02:00:00:00:35
Interface Type bond
Master interface: bridge
EVPN-MH: ES id 1 ES sysmac 00:00:00:00:01:11
protodown: off rc: startup-delay <<<<<<<<<<<<<<<<<
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
ES-bond member protodown display -
==================================
root@torm-11:mgmt:~# vtysh -c "show interface swp5"
Interface swp5 is up, line protocol is down
Link ups: 0 last: (never)
Link downs: 3 last: 2020/04/26 20:38:03.52
PTM status: disabled
vrf: default
index 7 metric 0 mtu 9152 speed 10000
flags: <UP,BROADCAST,MULTICAST>
Type: Ethernet
HWaddr: 00:02:00:00:00:35
Interface Type Other
Master interface: hostbond1
protodown: on rc: startup-delay <<<<<<<<<<<<<<<<
root@torm-11:mgmt:~#
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
Signed-off-by: Anuradha Karuppiah <anuradhak@cumulusnetworks.com>
Zebra's clear duplicate detect command is rpc converted.
There is condition where cli fails with human readable message.
Using northboun's errmsg buffer to display error message to
user.
Testing:
bharat# clear evpn dup-addr vni 1002 ip 2011:11::11
Error type: generic error
Error description: Requested IP's associated MAC aa:aa:aa:aa:aa:aa is still in duplicate state
bharat# clear evpn dup-addr vni 1002 ip 11.11.11.11
Error type: generic error
Error description: Requested IP's associated MAC aa:aa:aa:aa:aa:aa is still in duplicate state
Signed-off-by: Chirag Shah <chirag@nvidia.com>
With l2vni flap leading to duplicate entry creation
in l3vni's l2vni-list.
Use list sorted add with no duplicates.
root@TORC11:mgmt:~# show evpn vni 4001
VNI: 4001
Type: L3
Tenant VRF: vrf1
State: Up
...
L2 VNIs: 1000 1000 1000 0 0 1002
root@TORC11:mgmt:~# ip link set down vx-1002
root@TORC11:mgmt:~# ip link set up vx-1002
root@TORC11:mgmt:~# show evpn vni 4001
VNI: 4001
Type: L3
Tenant VRF: vrf1
State: Up
...
L2 VNIs: 1000 1000 1000 0 0 1002 1002
Ticket:CM-31545
Reviewed By:
Testing Done:
With Fix:
Multiple time flaps vni counts remained the same.
root@TORC11:mgmt:~# ip link set down vx-1002
root@TORC11:mgmt:~# ip link set up vx-1002
root@TORC11:mgmt:~# ip link set down vx-1002
root@TORC11:mgmt:~# ip link set up vx-1002
root@TORC11:mgmt:~# net show evpn vni 4001
VNI: 4001
Type: L3
Tenant VRF: vrf1
State: Up
...
L2 VNIs: 1000 1002
Signed-off-by: Chirag Shah <chirag@nvidia.com>
the walk routine is used by vxlan service to identify some contexts in
each specific network namespace, when vrf netns backend is used. that
walk mechanism is extended with some additional paramters to the walk
routine.
Signed-off-by: Philippe Guibert <philippe.guibert@6wind.com>
when duplicate address detection is observed, some incrementation,
some timing mechanisms need to be done. For that the main evpn
configuration is retrieved. Until now, the VRF that was storing the dad
config parameters was the same VRF that hosted the VXLAN interface. With
netns backend, this is not true, as the VXLAN interface is in the
same VRF as the bridge interface. The modification takes same definition
as in BGP, that is to say that there is a single bgp evpn instance, and
this is that instance that will give the correct config settings.
Signed-off-by: Philippe Guibert <philippe.guibert@6wind.com>
all network namespaces are read so as to collect interesting fdb and
neighbor tables for EVPN.
Signed-off-by: Philippe Guibert <philippe.guibert@6wind.com>
With vrf-lite mechanisms, it is possible to create layer 3 vnis by
creating a bridge interface in default vr, by creating a vxlan interface
that is attached to that bridge interface, then by moving the vxlan
interface to the wished vrf.
With vrf-netns mechanism, it is slightly different since bridged
interfaces can not be separated in different network namespaces. To make
it work, the setup consists in :
- creating a vxlan interface on default vrf.
- move the vxlan interface to the wished vrf ( with an other netns)
- create a bridge interface in the wished vrf
- attach the vxlan interface to that bridged interface
from that point, if BGP is enabled to advertise vnis in default vrf,
then vxlan interfaces are discovered appropriately in other vrfs,
provided that the link interface still resides in the vrf where l2vpn is
advertised.
to import ipv4 entries from a separate vrf, into the l2vpn, the
configuration of vni in the dedicated vrf + the advertisement of ipv4
entries in bgp vrf will import the entries in the bgp l2vpn.
the modification consists in parsing the vxlan interfaces in all network
namespaces, where the link resides in the same network namespace as the
bgp core instance where bgp l2vpn is enabled.
Signed-off-by: Philippe Guibert <philippe.guibert@6wind.com>
clone zebra_vxlan.c to create a file zebra_evpn.c for core
EVPN functions whilst retaining the history of zebra_vxlan.c
Signed-off-by: Pat Ruddy <pat@voltanet.io>
extract the neighbor uninstall part of
zebra_vxlan_handle_kernel_neigh_del into a new function
zebra_evpn_neigh_del_ip in zebra_evpn_neigh.c.
Signed-off-by: Pat Ruddy <pat@voltanet.io>
extract the neighbor uninstall part of process_remote_macip_add
into a new function zebra_evpn_neigh_remote_uninstall in
zebra_evpn_neigh.c.
Signed-off-by: Pat Ruddy <pat@voltanet.io>
extract the neighbor part of process_remote_macip_add into a new
function zebra_evpn_neigh_gw_macip_add in zebra_evpn_neigh.c.
Signed-off-by: Pat Ruddy <pat@voltanet.io>
extract the neighbor part of process_remote_macip_add into a new
function process_neigh_remote_macip_add in zebra_evpn_neigh.c.
Signed-off-by: Pat Ruddy <pat@voltanet.io>
clone zebra_vxlan.c to create a file zebra_evpn_neigh.c for neighbor
dB functions whilst retaining the history of zebra_vxlan.c
Signed-off-by: Pat Ruddy <pat@voltanet.io>
extract mac_gateway add code from zevi_gw_macip_add and move it to
a new generic function zebra_evpn_mac_gw_macip_add in zebra_evpn_mac.c
Signed-off-by: Pat Ruddy <pat@voltanet.io>
extract generic local mac add code from zebra_vxlan_local_mac_del
into a new function zebra_evpn_del_local_mac in zebra_evpn_mac.c
Signed-off-by: Pat Ruddy <pat@voltanet.io>
extract the local mac add code from zebra_vxlan_local_mac_add_update
and create a new generic local mac add function
zebra_evpn_add_update_local_mac
Signed-off-by: Pat Ruddy <pat@voltanet.io>
Move MAC add code from process_remote_macip_add in zebra_vxlan.c
to a generic function process_mac_remote_macip_add in
zebra_evpn_mac.c
Signed-off-by: Pat Ruddy <pat@voltanet.io>
clone zebra_vxlan.c to create a file zebra_evpn_mac.c for MAC dB
functions whilst retaining the history of zebra_vxlan.c
Signed-off-by: Pat Ruddy <pat@voltanet.io>
The main zebra_vni_t hash structure has been renamed to zebra_evpn_t
to allow for other transport underlays. Rename functions and variables
to reflect this change.
Signed-off-by: Pat Ruddy <pat@voltanet.io>