Now that there is actually support to load non-static information
(at least from fwupd perspective) it makes sense to support this
command in both tools.
The source URL allows us to comply with our various obligations when shipping
firmware built from GPL licensed sources. The details URL allows vendors to
include a link to a full HTML details page about the specific release.
Currently used structures were based on early libnitrokey definitions
(which were broken for some time). Corrected their sizes and elements,
and added tests.
Fixes#960
Signed-off-by: Richard Hughes <richard@hughsie.com>
It's currently a hodge podge of commands that can install files not
always invoking a reboot or shutdown.
Move the actual code into `fu-util-common.c` and make sure that all
`install` and `update` functions call it now.
Some aspects of the method for querying dock firmware do work in 'dell' plugin
but that is not useful for fwupd because it's incomplete.
Due to this the following error shows up in fwupd journal if run on a Dell system
when the new Dell dock is plugged in:
failed to add USB device 0bda:8153: failed to add device using on dell: invalid dock component request Query 3 0 2 4 0
Detect this scenario, and prevent showing errors in logs.
Unfortunately the previous fix (6131f5d) introduced this bug.
The code previously was actually looking for the non-zero case
which was correct, but non-obvious since `efi_guid_cmp` works like
`g_strcmp0` where a match returns zero.
So rather than revert 6131f5d make this completly explicit.
If the device is rebooted into a different shape, the plugin managing
the device may also be different.
This would be the case for plugins that just subclass the update_detach()
method, and leave to other plugins the actual required update procedure.
Affected drives should have a prominent statement in the update description,
possibly even the first line so it shows up by default in the updates panel.
Microsoft description about the Status is:
The Status field of the BGRT describes whether the image is currently
displayed on the screen. This is not applicable to the firmware update
display capsule.
Many thanks to Steven Chang for identifying this issue.
Fixes: https://github.com/hughsie/fwupd/issues/935
Do not unset the quirks when closing the device, the _NO_DFU_RUNTIME quirk is
needed when re-opening the device during detach.
Fixes https://github.com/hughsie/fwupd/issues/927
On any devices that normally would require checking for AC also
check that at least one battery on the system has at least 30% to
perform an update.
Fixes: #925