Author SHA1 Message Date
Mario Limonciello
791b596d00 ata: send ATA standby immediate when activating firmware
This should flush all remaining writes and make the drive safe to
update.
2019-03-26 06:30:23 -04:00
Richard Hughes
8a3ab68fcb ata: Support delayed activation
This will allow us to switch to the new firmware version during shutdown when
the filesystems have been remounted readonly.

Activating manually means we don't have to get the user to shutdown and then
do a fresh power-on, rather than the more usual restart.
2019-02-27 09:04:54 +00:00
Mario Limonciello
eb8b38f158 trivial: storage: Update minimum Dell component ID length to 6
Dell storage team confirmed that nothing shorter than 6 will ever
be used and so this heuristic can be stronger.
2019-02-08 16:06:14 +00:00
Richard Hughes
6b78d64987 Add fwupd_guid_from_string() to drop dep on uuid
This also allows us to write mixed-endian structures and adds tests. As part of
this commit we've also changed the API of something that's not yet been in any
tarball release, so no pitchforks please.
2019-02-06 14:48:04 +00:00
Richard Hughes
1bc432316a Defer the InstanceID->GUID hashing until after setup
This allows hardware from OEMs to *not* match generic firmware supplied by the
device manufacturer. The idea being, that the OEM will supply firmware that
will actually work on the device.

Based on a patch from Mario Limonciello, many thanks.
2019-02-06 08:02:16 +00:00
Mario Limonciello
2472e45ac6 ata: Check for USB enclosures as well
I noticed that a SATA drive connected to an USB2.x to ATA bridge was
recognized as internal otherwise.
2019-02-05 20:29:26 +00:00
Richard Hughes
b8c30b8732 Do not use efivar just to print a mixed endian GUID 2019-02-04 15:19:57 +00:00
Richard Hughes
65c81921b6 Add fu_device_add_instance_id() and prefer explicit conversion 2019-02-04 15:19:57 +00:00
Mario Limonciello
b503aa8650 ata: Add support for detecting Dell GUIDs
Similar to NVME, ATA drives distributed by Dell have special values
that should be used to designate fwupd GUIDs and only run correct
firmware.

When detecting Dell GUIDs remove the standard fwupd GUIDs.  "Generic"
firmware targeted to those GUIDs will fail to install.
2019-02-04 10:39:20 +00:00
Richard Hughes
0a26551bf3 ata: Default to the non-activation 0xE subcommand
During download and activation we have to reset the drive to apply the new
firmware. If the kernel gets an unexpected ATA reset then it might panic.
Default to activating the command on the next drive power-up to be safe.

Many thanks to the Dell storage team for the advice.
2019-02-01 06:13:38 -06:00
Richard Hughes
dd0264d0ef ata: Mark all devices as needing a reboot
Although not strictly required, I would feel a lot more warm and fuzzy knowing
the drives are running the new firmware ASAP.
2019-01-30 06:10:36 -06:00
Richard Hughes
0bf8ee810b ata: Add a new plugin to upgrade firmware on ATA/ATAPI hardware
Some of the ATA12 fixup code is by Mark Lord, taken from the hdparm project.

Fixes: https://github.com/hughsie/fwupd/issues/946
2019-01-29 22:28:09 +00:00