The BT qualification test SM/MAS/PKE/BV-01-C needs us to turn off
the MITM flag when pairing, and at the same time also set the io
capability to something other than no input no output.
Currently the MITM flag is only unset when the io capability is set
to no input no output, therefore the test cannot be executed.
This patch introduces a debugfs option to force MITM flag to be
turned off.
Signed-off-by: Archie Pusaka <apusaka@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch assigns the next free HCI device identifier to Bluetooth
devices based on VIRTIO devices.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
With the Read Local Simple Pairing Options command it is possible to
retrieve the support for max encryption key size supported by the
controller and also if the controller correctly verifies the ECDH public
key during pairing.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Reviewed-by: Alain Michaud <alainm@chromium.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
notifying using HCI_NOTIFY_CONN_ADD for SCO connection is generic in
case of mSBC audio. To differntiate SCO air mode introducing
HCI_NOTIFY_ENABLE_SCO_CVSD and HCI_NOTIFY_ENABLE_SCO_TRANSP.
Signed-off-by: Sathish Narsimman <sathish.narasimman@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
To handle BR/EDR devices, we first disable page scan and disconnect all
connected devices. Once that is complete, we add event filters (for
devices that can wake the system) and re-enable page scan.
Signed-off-by: Abhishek Pandit-Subedi <abhishekpandit@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This change introduces a wide band speech setting which allows higher
level clients to query the local controller support for wide band speech
as well as set the setting state when the radio is powered off.
Internally, this setting controls if erroneous data reporting is enabled
on the controller.
Signed-off-by: Alain Michaud <alainm@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch provides a mechanism for MGMT interface client to query the
capability of the controller to support WBS.
Signed-off-by: Alain Michaud <alainm@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This change simply fixes a few typos in the quirk definitions.
Signed-off-by: Alain Michaud <alainm@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Extended advertising Data is set during bluetooth initialization
by default which causes InvalidHCICommandParameters when setting
Extended advertising parameters.
As per Core Spec 5.2 Vol 2, PART E, Sec 7.8.53, for
advertising_event_property LE_LEGACY_ADV_DIRECT_IND does not
supports advertising data when the advertising set already
contains some, the controller shall return erroc code
'InvalidHCICommandParameters(0x12).
So it is required to remove adv set for handle 0x00. since we use
instance 0 for directed adv.
Signed-off-by: Sathish Narsimman <sathish.narasimman@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
The current codebase makes use of the zero-length array language
extension to the C90 standard, but the preferred mechanism to declare
variable-length types such as these ones is a flexible array member[1][2],
introduced in C99:
struct foo {
int stuff;
struct boo array[];
};
By making use of the mechanism above, we will get a compiler warning
in case the flexible array does not occur last in the structure, which
will help us prevent some kind of undefined behavior bugs from being
inadvertently introduced[3] to the codebase from now on.
Also, notice that, dynamic memory allocations won't be affected by
this change:
"Flexible array members have incomplete type, and so the sizeof operator
may not be applied. As a quirk of the original implementation of
zero-length arrays, sizeof evaluates to zero."[1]
This issue was found with the help of Coccinelle.
[1] https://gcc.gnu.org/onlinedocs/gcc/Zero-Length.html
[2] https://github.com/KSPP/linux/issues/21
[3] commit 7649773293 ("cxgb3/l2t: Fix undefined behaviour")
Signed-off-by: Gustavo A. R. Silva <gustavo@embeddedor.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
These adds the HCI definitions for handling CIS connections along with
ISO data packets.
Signed-off-by: Luiz Augusto von Dentz <luiz.von.dentz@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This handles LE PHY Update Complete event and store both tx_phy and
rx_phy into hci_conn.
Signed-off-by: Luiz Augusto von Dentz <luiz.von.dentz@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Changes made to add HCI Write Authenticated Payload timeout
command for LE Ping feature.
As per the Core Specification 5.0 Volume 2 Part E Section 7.3.94,
the following code changes implements
HCI Write Authenticated Payload timeout command for LE Ping feature.
Signed-off-by: Spoorthi Ravishankar Koppad <spoorthix.k@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This commit makes the kernel not send the next queued HCI command until
a command complete arrives for the last HCI command sent to the
controller. This change avoids a problem with some buggy controllers
(seen on two SKUs of QCA9377) that send an extra command complete event
for the previous command after the kernel had already sent a new HCI
command to the controller.
The problem was reproduced when starting an active scanning procedure,
where an extra command complete event arrives for the LE_SET_RANDOM_ADDR
command. When this happends the kernel ends up not processing the
command complete for the following commmand, LE_SET_SCAN_PARAM, and
ultimately behaving as if a passive scanning procedure was being
performed, when in fact controller is performing an active scanning
procedure. This makes it impossible to discover BLE devices as no device
found events are sent to userspace.
This problem is reproducible on 100% of the attempts on the affected
controllers. The extra command complete event can be seen at timestamp
27.420131 on the btmon logs bellow.
Bluetooth monitor ver 5.50
= Note: Linux version 5.0.0+ (x86_64) 0.352340
= Note: Bluetooth subsystem version 2.22 0.352343
= New Index: 80:C5:F2:8F:87:84 (Primary,USB,hci0) [hci0] 0.352344
= Open Index: 80:C5:F2:8F:87:84 [hci0] 0.352345
= Index Info: 80:C5:F2:8F:87:84 (Qualcomm) [hci0] 0.352346
@ MGMT Open: bluetoothd (privileged) version 1.14 {0x0001} 0.352347
@ MGMT Open: btmon (privileged) version 1.14 {0x0002} 0.352366
@ MGMT Open: btmgmt (privileged) version 1.14 {0x0003} 27.302164
@ MGMT Command: Start Discovery (0x0023) plen 1 {0x0003} [hci0] 27.302310
Address type: 0x06
LE Public
LE Random
< HCI Command: LE Set Random Address (0x08|0x0005) plen 6 #1 [hci0] 27.302496
Address: 15:60:F2:91:B2:24 (Non-Resolvable)
> HCI Event: Command Complete (0x0e) plen 4 #2 [hci0] 27.419117
LE Set Random Address (0x08|0x0005) ncmd 1
Status: Success (0x00)
< HCI Command: LE Set Scan Parameters (0x08|0x000b) plen 7 #3 [hci0] 27.419244
Type: Active (0x01)
Interval: 11.250 msec (0x0012)
Window: 11.250 msec (0x0012)
Own address type: Random (0x01)
Filter policy: Accept all advertisement (0x00)
> HCI Event: Command Complete (0x0e) plen 4 #4 [hci0] 27.420131
LE Set Random Address (0x08|0x0005) ncmd 1
Status: Success (0x00)
< HCI Command: LE Set Scan Enable (0x08|0x000c) plen 2 #5 [hci0] 27.420259
Scanning: Enabled (0x01)
Filter duplicates: Enabled (0x01)
> HCI Event: Command Complete (0x0e) plen 4 #6 [hci0] 27.420969
LE Set Scan Parameters (0x08|0x000b) ncmd 1
Status: Success (0x00)
> HCI Event: Command Complete (0x0e) plen 4 #7 [hci0] 27.421983
LE Set Scan Enable (0x08|0x000c) ncmd 1
Status: Success (0x00)
@ MGMT Event: Command Complete (0x0001) plen 4 {0x0003} [hci0] 27.422059
Start Discovery (0x0023) plen 1
Status: Success (0x00)
Address type: 0x06
LE Public
LE Random
@ MGMT Event: Discovering (0x0013) plen 2 {0x0003} [hci0] 27.422067
Address type: 0x06
LE Public
LE Random
Discovery: Enabled (0x01)
@ MGMT Event: Discovering (0x0013) plen 2 {0x0002} [hci0] 27.422067
Address type: 0x06
LE Public
LE Random
Discovery: Enabled (0x01)
@ MGMT Event: Discovering (0x0013) plen 2 {0x0001} [hci0] 27.422067
Address type: 0x06
LE Public
LE Random
Discovery: Enabled (0x01)
Signed-off-by: João Paulo Rechi Vita <jprvita@endlessm.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Add HCI_QUIRK_USE_BDADDR_PROPERTY to allow controllers to retrieve
the public Bluetooth address from the firmware node property
'local-bd-address'. If quirk is set and the property does not exist
or is invalid the controller is marked as unconfigured.
Signed-off-by: Matthias Kaehlcke <mka@chromium.org>
Reviewed-by: Balakrishna Godavarthi <bgodavar@codeaurora.org>
Tested-by: Balakrishna Godavarthi <bgodavar@codeaurora.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Add the definitions for adding entries to the LE resolve list and
removing entries from the LE resolve list. When the LE resolve list
gets changed via HCI commands make sure that the internal storage of
the resolve list entries gets updated.
Signed-off-by: Ankit Navik <ankit.p.navik@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Add the definitions for LE address resolution enable HCI commands.
When the LE address resolution enable gets changed via HCI commands
make sure that flag gets updated.
Signed-off-by: Ankit Navik <ankit.p.navik@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Using HCI_VENDOR_PKT for vendor specific events does work since it has
also the value 0xff, but it is actually the packet type indicator
constant and not the event constant. So introduce HCI_EV_VENDOR and
use it.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Add a new quirk HCI_QUIRK_NON_PERSISTENT_SETUP allowing that a quirk that
runs setup() after every open() and not just after the first open().
Signed-off-by: Sean Wang <sean.wang@mediatek.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch adds support for advertising in primary and secondary
channel on different PHYs. User can add the phy preference in
the flag based on which phy type will be added in extended
advertising parameter would be set.
@ MGMT Command: Add Advertising (0x003e) plen 11
Instance: 1
Flags: 0x00000200
Advertise in CODED on Secondary channel
Duration: 0
Timeout: 0
Advertising data length: 0
Scan response length: 0
< HCI Command: LE Set Extended Advertising Enable (0x08|0x0039) plen 2
Extended advertising: Disabled (0x00)
Number of sets: Disable all sets (0x00)
> HCI Event: Command Complete (0x0e) plen 4
LE Set Extended Advertising Enable (0x08|0x0039) ncmd 2
Status: Success (0x00)
< HCI Command: LE Set Extended Advertising Parameters (0x08|0x0036) plen 25
Handle: 0x00
Properties: 0x0000
Min advertising interval: 1280.000 msec (0x0800)
Max advertising interval: 1280.000 msec (0x0800)
Channel map: 37, 38, 39 (0x07)
Own address type: Random (0x01)
Peer address type: Public (0x00)
Peer address: 00:00:00:00:00:00 (OUI 00-00-00)
Filter policy: Allow Scan Request from Any, Allow Connect Request from Any (0x00)
TX power: 127 dbm (0x7f)
Primary PHY: LE Coded (0x03)
Secondary max skip: 0x00
Secondary PHY: LE Coded (0x03)
SID: 0x00
Scan request notifications: Disabled (0x00)
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This event comes after connection complete event for incoming
connections. Since we now have different random address for
each instance, conn resp address is assigned from this event.
As of now only connection part is handled as we are not
enabling duration or max num of events while starting ext adv.
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This basically sets the random address for the adv instance
Random address can be set only if the instance is created which
is done in Set ext adv param.
Random address and rpa expire timer and flags have been added
to adv instance which will be used when the respective
instance is scheduled.
This introduces a hci_get_random_address() which returns the
own address type and random address (rpa or nrpa) based
on the instance flags and hdev flags. New function is required
since own address type should be known before setting adv params
but address can be set only after setting params.
< HCI Command: LE Set Advertising Set Random Address (0x08|0x0035) plen 7
Advertising handle: 0x00
Advertising random address: 3C:8E:56:9B:77:84 (OUI 3C-8E-56)
> HCI Event: Command Complete (0x0e) plen 4
LE Set Advertising Set Random Address (0x08|0x0035) ncmd 1
Status: Success (0x00)
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
If ext adv is enabled then use ext adv to disable as well.
Also remove the adv set during LE disable.
< HCI Command: LE Set Extended Advertising Enable (0x08|0x0039) plen 2
Extended advertising: Disabled (0x00)
Number of sets: Disable all sets (0x00)
> HCI Event: Command Complete (0x0e) plen 4
LE Set Extended Advertising Enable (0x08|0x0039) ncmd 2
Status: Success (0x00)
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch implements Set Ext Adv data and Set Ext Scan rsp data
if controller support extended advertising.
Currently the operation is set as Complete data and fragment
preference is set as no fragment
< HCI Command: LE Set Extended Advertising Data (0x08|0x0037) plen 35
Handle: 0x00
Operation: Complete extended advertising data (0x03)
Fragment preference: Minimize fragmentation (0x01)
Data length: 0x15
16-bit Service UUIDs (complete): 2 entries
Heart Rate (0x180d)
Battery Service (0x180f)
Name (complete): Test LE
Company: Google (224)
Data: 0102
> HCI Event: Command Complete (0x0e) plen 4
LE Set Extended Advertising Data (0x08|0x0037) ncmd 1
Status: Success (0x00)
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch basically replaces legacy adv with extended adv
based on the controller support. Currently there is no
design change. ie only one adv set will be enabled at a time.
This also adds tx_power in instance and store whatever returns
from Set_ext_parameter, use the same in adv data as well.
For instance 0 tx_power is stored in hdev only.
< HCI Command: LE Set Extended Advertising Parameters (0x08|0x0036) plen 25
Handle: 0x00
Properties: 0x0010
Use legacy advertising PDUs: ADV_NONCONN_IND
Min advertising interval: 1280.000 msec (0x0800)
Max advertising interval: 1280.000 msec (0x0800)
Channel map: 37, 38, 39 (0x07)
Own address type: Random (0x01)
Peer address type: Public (0x00)
Peer address: 00:00:00:00:00:00 (OUI 00-00-00)
Filter policy: Allow Scan Request from Any, Allow Connect Request from Any (0x00)
TX power: 127 dbm (0x7f)
Primary PHY: LE 1M (0x01)
Secondary max skip: 0x00
Secondary PHY: LE 1M (0x01)
SID: 0x00
Scan request notifications: Disabled (0x00)
> HCI Event: Command Complete (0x0e) plen 5
LE Set Extended Advertising Parameters (0x08|0x0036) ncmd 1
Status: Success (0x00)
TX power (selected): 7 dbm (0x07)
< HCI Command: LE Set Extended Advertising Enable (0x08|0x0039) plen 6
Extended advertising: Enabled (0x01)
Number of sets: 1 (0x01)
Entry 0
Handle: 0x00
Duration: 0 ms (0x00)
Max ext adv events: 0
> HCI Event: Command Complete (0x0e) plen 4
LE Set Extended Advertising Enable (0x08|0x0039) ncmd 2
Status: Success (0x00)
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch reads the number of advertising sets in the controller
during init and save it in hdev.
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch defines the extended ADV types and handle it in ADV report.
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This also add macros for checking LMP support for different
pkt_types
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
1M is mandatory to be supported by LE controllers and the same
would be set in power on. This patch defines hdev flags for
LE PHYs and set 1M to default.
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This implements extended LE craete connection and enhanced
LE conn complete event if the controller supports.
For now it is as good as legacy LE connection and event as
no new features in the extended connection is handled.
< HCI Command: LE Extended Create Connection (0x08|0x0043) plen 26
Filter policy: White list is not used (0x00)
Own address type: Public (0x00)
Peer address type: Random (0x01)
Peer address: DB:7E:2E:1D:85:E8 (Static)
Initiating PHYs: 0x01
Entry 0: LE 1M
Scan interval: 60.000 msec (0x0060)
Scan window: 60.000 msec (0x0060)
Min connection interval: 50.00 msec (0x0028)
Max connection interval: 70.00 msec (0x0038)
Connection latency: 0 (0x0000)
Supervision timeout: 420 msec (0x002a)
Min connection length: 0.000 msec (0x0000)
Max connection length: 0.000 msec (0x0000)
> HCI Event: Command Status (0x0f) plen 4
LE Extended Create Connection (0x08|0x0043) ncmd 2
Status: Success (0x00)
> HCI Event: LE Meta Event (0x3e) plen 31
LE Enhanced Connection Complete (0x0a)
Status: Success (0x00)
Handle: 3585
Role: Master (0x00)
Peer address type: Random (0x01)
Peer address: DB:7E:2E:1D:85:E8 (Static)
Local resolvable private address: 00:00:00:00:00:00 (Non-Resolvable)
Peer resolvable private address: 00:00:00:00:00:00 (Non-Resolvable)
Connection interval: 67.50 msec (0x0036)
Connection latency: 0 (0x0000)
Supervision timeout: 420 msec (0x002a)
Master clock accuracy: 0x00
@ MGMT Event: Device Connected (0x000b) plen 40
LE Address: DB:7E:2E:1D:85:E8 (Static)
Flags: 0x00000000
Data length: 27
Name (complete): Designer Mouse
Appearance: Mouse (0x03c2)
Flags: 0x05
LE Limited Discoverable Mode
BR/EDR Not Supported
16-bit Service UUIDs (complete): 1 entry
Human Interface Device (0x1812)
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch enables Extended ADV report event if extended scanning
is supported in the controller and process the same.
The new features are not handled and for now its as good as
legacy ADV report.
> HCI Event: LE Meta Event (0x3e) plen 53
LE Extended Advertising Report (0x0d)
Num reports: 1
Entry 0
Event type: 0x0013
Props: 0x0013
Connectable
Scannable
Use legacy advertising PDUs
Data status: Complete
Legacy PDU Type: ADV_IND (0x0013)
Address type: Random (0x01)
Address: DB:7E:2E:1A:85:E8 (Static)
Primary PHY: LE 1M
Secondary PHY: LE 1M
SID: 0x00
TX power: 0 dBm
RSSI: -90 dBm (0xa6)
Periodic advertising invteral: 0.00 msec (0x0000)
Direct address type: Public (0x00)
Direct address: 00:00:00:00:00:00 (OUI 00-00-00)
Data length: 0x1b
0f 09 44 65 73 69 67 6e 65 72 20 4d 6f 75 73 65 ..Designer Mouse
03 19 c2 03 02 01 05 03 03 12 18 ...........
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This implements Set extended scan param and set extended scan enable
commands and use it for start LE scan based on controller support.
The new features added in these commands are setting of new PHY for
scanning and setting of scan duration. Both features are disabled
for now, meaning only 1M PHY is set and scan duration is set to 0
which means that scanning will be done untill scan disable is called.
< HCI Command: LE Set Extended Scan Parameters (0x08|0x0041) plen 8
Own address type: Random (0x01)
Filter policy: Accept all advertisement (0x00)
PHYs: 0x01
Entry 0: LE 1M
Type: Active (0x01)
Interval: 11.250 msec (0x0012)
Window: 11.250 msec (0x0012)
> HCI Event: Command Complete (0x0e) plen 4
LE Set Extended Scan Parameters (0x08|0x0041) ncmd 1
Status: Success (0x00)
< HCI Command: LE Set Extended Scan Enable (0x08|0x0042) plen 6
Extended scan: Enabled (0x01)
Filter duplicates: Enabled (0x01)
Duration: 0 msec (0x0000)
Period: 0.00 sec (0x0000)
> HCI Event: Command Complete (0x0e) plen 4
LE Set Extended Scan Enable (0x08|0x0042) ncmd 2
Status: Success (0x00)
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch increases the connection timeout for LE connections that are
triggered by the advertising report to 4 seconds.
It has been observed that devices equipped with wifi+bt combo SoC fail
to create a connection with BLE devices due to their coexistence issues.
Increasing this timeout gives them enough time to complete the
connection with success.
Signed-off-by: Konrad Zapałowicz <konrad.zapalowicz@canonical.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
If the LE Set Default PHY command is supported, the indicate to the
controller that the host has no preferences for transmitter PHY or
receiver PHY selection.
Issuing this command gives the controller a clear indication that other
PHY can be selected if available.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
If the Channel Selection Algorithm #2 feature is supported, then enable
the new LE Channel Selection Algorithm event.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This command is used to retrieve the current state and basic
information of a controller. It is typically used right after
getting the response to the Read Controller Index List command
or an Index Added event (or its extended counterparts).
When any of the values in the EIR_Data field changes, the event
Extended Controller Information Changed will be used to inform
clients about the updated information.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Michał Narajowski <michal.narajowski@codecoup.pl>
Instead of hiding everything behind a general managment events flag,
introduce indivdual flags that allow fine control over which events are
send to a given management channel.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This patch assigns the next free HCI device identifier to Bluetooth
devices based on the Qualcomm Shared Memory channels.
Signed-off-by: Bjorn Andersson <bjorn.andersson@sonymobile.com>
Signed-off-by: Bjorn Andersson <bjorn.andersson@linaro.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
The HCI_BREDR naming is confusing since it actually stands for Primary
Bluetooth Controller. Which is a term that has been used in the latest
standard. However from a legacy point of view there only really have
been Basic Rate (BR) and Enhanced Data Rate (EDR). Recent versions of
Bluetooth introduced Low Energy (LE) and made this terminology a little
bit confused since Dual Mode Controllers include BR/EDR and LE. To
simplify this the name HCI_PRIMARY stands for the Primary Controller
which can be a single mode or dual mode controller.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Extend the set of possible HCI bus types with SPI and I2C.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Introduce a limited privacy mode indicated by value 0x02 to the mgmt
Set Privacy command.
With value 0x02 the kernel will use privacy mode with a resolvable
private address. In case the controller is bondable and discoverable
the identity address will be used.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This flag just tells us whether hdev->adv_instances is empty or not.
We can equally well use the list_empty() function to get this
information.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
In some cases it may be important to get the exact HCI status rather
than the converted HCI-to-errno value. Add an optional return
parameter to the hci_req_sync() API to allow for this. Since there are
no good HCI translation candidates for cancelation and timeout, use
the "unknown" status code for those cases.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Before the vendor specific setup stage is triggered call back into the
core to trigger an internal notification event. That event is used to
send an index update to the monitor interface. With that specific event
it is possible to update userspace with manufacturer information before
any HCI command has been executed. This is useful for early stage
debugging of vendor specific initialization sequences.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
If the diagnostic settings are not persistent over HCI Reset, then this
quirk can be used to tell the Bluetoth core about it. This will ensure
that the settings are programmed correctly when the controller is
powered up.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This adds a new debugfs entry for enabling and disabling the vendor
diagnostic mode. It is only exposed for drivers that provide the
set_diag driver callback and actually have an option for vendor
specific diagnostic information.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Introduce hci_recv_diag function for HCI drivers to allow sending vendor
specific diagnostic messages into the Bluetooth core stack. The messages
are not processed, but they are forwarded to the monitor channel and can
be retrieved by user space diagnostic tools.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
When opening the HCI transport via hdev->open send HCI_DEV_OPEN event
and when closing the HCI transport via hdev->close send HCI_DEV_CLOSE.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Since Bluetooth 3.0 there's a HCI command available for reading the
encryption key size of an BR/EDR connection. This information is
essential e.g. for generating an LTK using SMP over BR/EDR, so store
it as part of struct hci_conn.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
When establishing a Bluetooth LE connection, read the remote used
features mask to determine which features are supported. This was
not really needed with Bluetooth 4.0, but since Bluetooth 4.1 and
also 4.2 have introduced new optional features, this becomes more
important.
This works the same as with BR/EDR where the connection enters the
BT_CONFIG stage and hci_connect_cfm call is delayed until the remote
features have been retrieved. Only after successfully receiving the
remote features, the connection enters the BT_CONNECTED state.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Since Bluetooth 4.1 there are two additional values for SSP OOB data,
namely C-256 and R-256. This patch updates the EIR definitions to take
into account both the 192 and 256 bit variants of C and R.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch introduces the HCI_ADVERTISING_INSTANCE setting, which is set
when an at least one advertising instance has been added using the
"Add Advertising" mgmt command. This patch also adds a macro definition
for the EIR_APPEARANCE field type.
Signed-off-by: Arman Uguray <armansito@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Some controllers allow both LE scan and BR/EDR inquiry to run at
the same time, while others allow only one, LE SCAN or BR/EDR
inquiry at given time.
Since this is specific to each controller, add a new quirk setting
that allows drivers to tell the core wether given controller can
do both LE scan and BR/EDR inquiry at same time.
Signed-off-by: Jakub Pawlowski <jpawlowski@google.com>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
When a different user requests a new set of local out-of-band data, then
inform all previous users that the data has been updated. To limit the
scope of users, the updates are limited to previous users. If a user has
never requested out-of-band data, it will also not see the update.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The LE Secure Connections Confirmation Value and LE Secure Connections
Random Value contants are required for the out-of-band data and so
just define them.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The OOB data requires to include LE Bluetooth Device Address and LE Role
and so add the type constants for these fields.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Changes to the global configuration updates like settings, class of
device, name etc. can be received by every user. They are allowed to
read them in the first place so provide the updates via events as
well. Otherwise untrusted users start polling for updates and that
is not a desired behavior.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Providing a global trusted flag for management control sockets provides
an easy way for identifying sockets and imposing restriction on it. For
now all management sockets are trusted since they require CAP_NET_ADMIN.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This introduces support for using Extended Index Added and Extended
Index Removed events. These events contain the controller type and
also the hardware bus information from the driver.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
For sending Index Added, Index Removed, Unconfigured Index Added and
Unconfigured Index Removed managment events the new helper functions
allows taking into account if these events are enabled for a certain
management socket or not.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
With the extension of hdev->dev_flags utilizing a bitmap now, the space
is no longer restricted. Merge the hdev->dbg_flags into hdev->dev_flags
to save space on 64-bit architectures. On 32-bit architectures no size
reduction happens.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The hdev->dev_flags field has outgrown itself on 32-bit systems. So
instead of hacking around it, switch to using DECLARE_BITMAP.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The patch adds a second advertising setting that allows switching of the
controller into connectable mode independent of the global connectable
setting.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
To maximize the usability of the Fast Connectable feature we should make
it possible to set (or unset) it at any given moment. This means
removing the dependency on the 'connectable' setting as well as the
'powered' setting. The former makes also sense since page scan may get
enabled through add_device even if 'connectable' is false. To keep the
setting available over power cycles its flag also needs to be removed
from the flags that are cleared upon HCI_Reset.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch adds this missing structure for processing the result of the
HCI Delete Stored Link Key command.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This patch adds the missing commmand structure and command complete
structure for the HCI Read Store Link Key command.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The HCI_QUIRK_FIXUP_INQUIRY_MODE option allows to force Inquiry Result
with RSSI setting on controllers that do not indicate support for it,
but where it is known to be fully functional.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The force_sc_support debugfs option was introduced to easily work with
pre-production Bluetooth 4.1 silicon. This option is no longer needed
since controllers supporting BR/EDR Secure Connections feature are now
available.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The force_lesc_support debugfs option never really worked. It has a race
condition between creating the debugfs entry and registering the L2CAP
fixed channel for BR/EDR SMP support.
Also this has been replaced with a working force_bredr_smp debugfs
switch that developers can use now.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Testing cross-transport pairing that starts on BR/EDR is only valid when
using a controller with BR/EDR Secure Connections. Devices will indicate
this by providing BR/EDR SMP fixed channel over L2CAP. To allow testing
of this feature on Bluetooth 4.0 controller or controllers without the
BR/EDR Secure Connections features, introduce a force_bredr_smp debugfs
option that allows faking the required AES connection.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Some controllers advertise support for Bluetooth 1.2 specification,
but they do not support the HCI Read Local Supported Commands command.
If that is the case, then the driver can quirk the behavior and force
the core to skip this command. This will allow removing vendor specific
checks out of the core.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This patch adds the structures for HCI commands and events of the
LE Data Length Extension feature from Bluetooth 4.2 specification.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
When the controller supports the Extended Scanner Filter Policies, it
supports the LE Direct Advertising Report event. However by default
that event is blocked by the LE event mask. It is required to enable
it during controller setup.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This patch adds the event id and data structures for the LE Direct
Advertising Report event.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
All Bluetooth commands and events are ordered by its opcode or event
id, but for some reason this one now stands out. So move it to its
correct spot in the list.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The Bluetooth core specification defines the value 127 as invalid for
RSSI values. So instead of hard coding it, lets add a constant for it.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
To make it possible to use LE SC functionality over BR/EDR with pre-4.1
controllers (that do not support BR/EDR SC links) it's useful to be able
to force LE SC operations even over a traditional SSP protected link.
This patch adds a debugfs switch to force a special debug flag which is
used to skip the checks for BR/EDR SC support.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
The common short form of "randomizer" is "rand" in many places
(including the Bluetooth specification). The shorter version also makes
for easier to read code with less forced line breaks. This patch renames
all occurences of "randomizer" to "rand" in the Bluetooth subsystem
code.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Some drivers require knowledge of what connection handle is assigned
to what connection link type (ACL or SCO/eSCO). Instead of having each
driver implement connection tracking, provide a simple helper function
for lookup of the link type.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Some vendors decide to use a strict duplicate filter policy that only
filters on Bluetooth device addresses. This means that when the RSSI
changes, these devices are not reported again. During discovery it is
useful to actually get the RSSI updates.
Since this is specific to each controller, add a new quirk setting
that allows drivers to tell the core what kind of filtering policy
the controller uses.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
When the HCI_Hardware_Error event is send by the controller or
injected by the driver, then at least print an error message.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The core specification defines valid values for the
HCI_Reject_Synchronous_Connection_Request command to be 0x0D-0x0F. So
far the code has been using HCI_ERROR_REMOTE_USER_TERM (0x13) which is
not a valid value and is therefore being rejected by some controllers:
> HCI Event: Connect Request (0x04) plen 10
bdaddr 40:6F:2A:6A:E5:E0 class 0x000000 type eSCO
< HCI Command: Reject Synchronous Connection (0x01|0x002a) plen 7
bdaddr 40:6F:2A:6A:E5:E0 reason 0x13
Reason: Remote User Terminated Connection
> HCI Event: Command Status (0x0f) plen 4
Reject Synchronous Connection (0x01|0x002a) status 0x12 ncmd 1
Error: Invalid HCI Command Parameters
This patch introduces a new define for a value from the valid range
(0x0d == Connection Rejected Due To Limited Resources) and uses it
instead for rejecting incoming connections.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
The HCI_PAIRABLE flag isn't actually controlling whether we're pairable
but whether we're bondable. Therefore, rename it accordingly.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
If the Bluetooth controller supports Get MWS Transport Layer
Configuration command, then issue it during initialization.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
If the Bluetooth controller supports Read Local Supported Codecs
command, then issue it during initialization so that the list of
codecs is known.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
All HCI commands and events, including LE ones, use 0x00 for master role
and 0x01 for slave role. It makes therefore sense to add generic defines
for these instead of the current LE_CONN_ROLE_MASTER. Having clean
defines will also make it possible to provide simpler internal APIs.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
The support for LE encryption is optional. When encryption is not
supported then also do not enable the encryption related events.
This moves the event mask setting to the third initialization
stage to ensure that the LE features are available.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
All the HCI sockets and ioctl based definitions have been in a global
header file that also includes all the HCI protocol structures. To
make this a bit cleaner, move them into its own file.
This also adjusts fs/compat_ioctl.c to only include this new file
and not all the protocol structures that are not needed.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The Authenticated Payload Timeout Expired event is valid for
controllers with BR/EDR Secure Connections support, but also for
LE only controllers supporting LE Ping feature. When either of them
is available enable this event. Previous it was not enabled when
the controller was only supporting LE operation.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Having a single HCI_ADVERTISING flag is problematic since it tries to
track both the real advertising state and the corresponding mgmt
setting. To make the logic simpler and more reliable add a new flag that
only tracks the actual advertising state that has been written to the
controller.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
When we establish connections as a consequence of receiving an
advertising report it makes no sense to wait the normal 20 second LE
connection timeout. This patch modifies the hci_connect_le function to
take an extra timeout value and uses a lower 2 second timeout for the
auto-connection case. This timeout is intentionally chosen to be just a
bit higher than the 1.28 second timeout that High Duty Cycle Advertising
uses.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
When the external configuration triggers the switch to a configured
controller, it means the setup needs to be run. Controllers that start
out unconfigured have only run limited set of HCI commands. This is
not enough for complete operation and thus run the setup procedure
before announcing the new controller index.
This introduces HCI_CONFIG flag as companion to HCI_SETUP flag. The
HCI_SETUP flag is only used once for the initial setup procedure. And
during that procedure hdev->setup driver callback is called. With the
new HCI_CONFIG the switch from unconfigured to configured state is
triggering the same setup procedure just without hdev->setup. This
is required since bringing a controller back to unconfigured state
from configured state is possible.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The Set External Configuration management command allows for switching
between configured and unconfigured start if HCI_QURIK_EXTERNAL_CONFIG
is set by the transport driver.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
When a controller requires external configuration, then setting this
quirk will allow indicating this.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
When a Bluetooth controller does not have a valid public Bluetooth
address, then allow the driver to indicate this. If the quirk is
set, the Bluetooth core will switch to unconfigured state first
and will allow userspace to configure the address before starting
the full initialization of the controller.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The current existing device quirks are not documented. So instead of
spreading bits and pieces somewhere in the code, add proper comments
on where these quirks can be used and what behavior they change.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
With the new unconfigured controller state it is possible to provide a
fully functional HCI transport, but disable the higher level operations
that would normally happen. This way userspace can try to configure the
controller before releases the unconfigured state.
The internal state is represented by HCI_UNCONFIGURED. This replaces the
HCI_QUIRK_RAW_DEVICE quirk as internal state representation. This is now
a real state and drivers can use the quirk to actually trigger this
state. In the future this will allow a more fine grained switching from
unconfigured state to configured state for controller inititialization.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The Bluetooth 4.1 introduces a new LE meta event called "LE Remote
Connection Parameter Request" event. In order to the controller
sends this event to host, we should enable it during controller
initialization.
Signed-off-by: Andre Guedes <andre.guedes@openbossa.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch adds support for LE Connection Parameters Request Link
Layer control procedure introduced in Core spec 4.1. This procedure
allows a Peripheral or Central to update the Link Layer connection
parameters of an established connection.
Regarding the acceptance of connection parameters, the LL procedure
follows the same approach of L2CAP procedure (see l2cap_conn_param_
update_req function). We accept any connection parameters values as
long as they are within the valid range.
Signed-off-by: Andre Guedes <andre.guedes@openbossa.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch adds support for storing the local and piconet clock values
from the HCI_Read_Clock command response to the hci_dev and hci_conn
structs. This will be later used in another patch to implement support
for the Get Clock Info mgmt command.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
When the connection is in master role and it is going to be
disconnected based on the disconnection timeout, then send
the HCI_Read_Clock_Offset command in an attempt to update the
clock offset value in the inquiry cache.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
To pave the way for actively using debug keys for pairing this patch
adds a new HCI_USE_DEBUG_KEYS flag for the purpose. When the flag is set
we issue a HCI_Write_SSP_Debug mode whenever HCI_Write_SSP_Mode(0x01)
has been issued as well as before issuing a HCI_Write_SSP_Mode(0x00)
command.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
We're planning to add a flag to actively use debug keys in addition to
simply just accepting them, which makes the current generically named
DEBUG_KEYS flag a bit confusing. Since the flag in practice affects
whether the kernel keeps debug keys around or not rename it to
HCI_KEEP_DEBUG_KEYS.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
When the LE controller changes its connection parameters, it will send
a connection parameter update event. Make sure that the new set of
parameters are stored in hci_conn struct and thus will properly update
the previous values retrieved from the connection complete event.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Create a CoC dynamically instead of one fixed channel for communication
to peer devices.
Signed-off-by: Jukka Rissanen <jukka.rissanen@linux.intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
All the special settings configured via debugfs are either developer
only options or temporary solutions. To not clutter the standard flags,
move them to their own dbg_flags entry.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
These defines were probably put in to track authenticated vs
unauthenticated LTKs, however since the LTK struct has a separate
boolean authenticated member these were never used.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
The LTK type has really nothing to do with HCI so it makes more sense to
have these in smp.h than hci.h. This patch moves the defines to smp.h
and removes the HCI_ prefix in the same go.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
We never store the "master" type of STKs since we request encryption
directly with them so we only need one STK type (the one that's
looked-up on the slave side). Simply remove the unnecessary define and
rename the _SLAVE one to the shorter form.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch adds support to store local TX power level for connection
when reply for HCI_Read_Transmit_Power_Level is received.
Signed-off-by: Andrzej Kaczmarek <andrzej.kaczmarek@tieto.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch adds support to store RSSI for connection when reply for
HCI_Read_RSSI is received.
Signed-off-by: Andrzej Kaczmarek <andrzej.kaczmarek@tieto.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
When we're in peripheral mode (HCI_ADVERTISING flag is set) the most
natural mapping of connect() is to perform directed advertising to the
peer device.
This patch does the necessary changes to enable directed advertising and
keeps the hci_conn state as BT_CONNECT in a similar way as is done for
central or BR/EDR connection initiation.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
The stop_scan_complete function was used as an intermediate step before
doing the actual connection creation. Since we're using hci_request
there's no reason to have this extra function around, i.e. we can simply
put both HCI commands into the same request.
The single task that the intermediate function had, i.e. indicating
discovery as stopped is now taken care of by a new
HCI_LE_SCAN_INTERRUPTED flag which allows us to do the discovery state
update when the stop scan command completes.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
LE connection attempts do not have a controller side timeout in the same
way as BR/EDR has (in form of the page timeout). Since we always do
scanning before initiating connections the attempts are always expected
to succeed in some reasonable time.
This patch adds a timer which forces a cancellation of the connection
attempt within 20 seconds if it has not been successful by then. This
way we e.g. ensure that mgmt_pair_device times out eventually and gives
an error response.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch adds defines for the initiator filter policy parameter values
of the HCI_LE_Create_Connection command. They will be used in a
subsequent patch to check whether we should have a timeout for the
connection attempt or not.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
The random numbers in Bluetooth Low Energy are 64-bit numbers and should
also be little endian since the HCI specification is little endian.
Change the whole Low Energy pairing to use __le64 instead of a byte
array.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
If some of the cleanup commands caused by mgmt_set_powered(off) never
complete we should still force the adapter to be powered down. This is
rather easy to do since hdev->power_off is already a delayed work
struct. This patch schedules this delayed work if at least one HCI
command was sent by the cleanup procedure.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Add the definitions for clearing the LE white list, adding entries to
the LE white list and removing entries from the LE white list.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Some LE controllers don't support scanning and creating a connection
at the same time. So we should always stop scanning in order to
establish the connection.
Since we may prematurely stop the discovery procedure in favor of
the connection establishment, we should also cancel hdev->le_scan_
disable delayed work and set the discovery state to DISCOVERY_STOPPED.
This change does a small improvement since it is not mandatory the
user stops scanning before connecting anymore. Moreover, this change
is required by upcoming LE auto connection mechanism in order to work
properly with controllers that don't support background scanning and
connection establishment at the same time.
In future, we might want to do a small optimization by checking if
controller is able to scan and connect at the same time. For now,
we want the simplest approach so we always stop scanning (even if
the controller is able to carry out both operations).
Signed-off-by: Andre Guedes <andre.guedes@openbossa.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch adds a timer for updating the local RPA periodically. The
default timeout is set to 15 minutes.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This code adds a HCI_PRIVACY flag to track whether Privacy support is
enabled (meaning we have a local IRK) and makes sure the IRK is
distributed during SMP key distribution in case this flag is set.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
The own_address_type debugfs option does not providing enough
flexibity for interacting with the upcoming LE privacy support.
What really is needed is an option to force using the static address
compared to the public address. The new force_static_address debugfs
option does exactly that. In addition it is also only available when
the controller does actually have a public address. For single mode
LE only controllers this option will not be available.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This patch implements the Load IRKs command for the management
interface. The command is used to load the kernel with the initial set
of IRKs. It also sets a HCI_RPA_RESOLVING flag to indicate that we can
start requesting devices to distribute their IRK to us.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
The LTK key types available right now are unauthenticated and
authenticated ones. Provide two simple constants for it.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
For debugging purposes of Secure Connection Only support a simple
debugfs entry is used to indicate if this mode is active or not.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The security level 4 is a new strong security requirement that is based
around 128-bit equivalent strength for link and encryption keys required
using FIPS approved algorithms. Which means that E0, SAFER+ and P-192
are not allowed. Only connections created with P-256 resulting from
using Secure Connections support are allowed.
This security level needs to be enforced when Secure Connection Only
mode is enabled for a controller or a service requires FIPS compliant
strong security. Currently it is not possible to enable either of
these two cases. This patch just puts in the foundation for being
able to handle security level 4 in the future.
It should be noted that devices or services with security level 4
requirement can only communicate using Bluetooth 4.1 controllers
with support for Secure Connections. There is no backward compatibilty
if used with older hardware.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The Bluetooth 4.1 specification with Secure Connections support has
just been released and controllers with this feature are still in
an early stage.
A handful of controllers have already support for it, but they do
not always identify this feature correctly. This debugfs entry
allows to tell the kernel that the controller can be treated as
it would fully support Secure Connections.
Using debugfs to force Secure Connections support of course does
not make this feature magically appear in all controllers. This
is a debug functionality for early adopters. Once the majority
of controllers matures this quirk will be removed.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The MGMT_SETTING_SECURE_CONN setting is used to track the support and
status for Secure Connections from the management interface. For HCI
based tracking HCI_SC_ENABLED flag is used.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
With the introduction of Secure Connections, the list of link key types
got extended by P-256 versions of authenticated and unauthenticated
link keys.
To avoid any confusion the previous authenticated and unauthenticated
link key types got ammended with a P912 postfix. And the two new keys
have a P256 postfix now. Existing code using the previous definitions
has been adjusted.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The Secure Connections feature introduces the support for P-256 strength
pairings (compared to P-192 with Secure Simple Pairing). This however
means that for out-of-band pairing the hash and randomizer needs to be
differentiated. Two new commands are introduced to handle the possible
combinations of P-192 and P-256. This add the HCI command definition
for both.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The Secure Connections feature is optional and host stacks have to
manually enable it. This add the HCI command definiton for reading
and writing this setting.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The support for Secure Connections introduces two new controller
features and one new host feature.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Some controller pretend they support the Delete Stored Link Key command,
but in reality they really don't support it.
< HCI Command: Delete Stored Link Key (0x03|0x0012) plen 7
bdaddr 00:00:00:00:00:00 all 1
> HCI Event: Command Complete (0x0e) plen 4
Delete Stored Link Key (0x03|0x0012) ncmd 1
status 0x11 deleted 0
Error: Unsupported Feature or Parameter Value
Not correctly supporting this command causes the controller setup to
fail and will make a device not work. However sending the command for
controller that handle stored link keys is important. This quirk
allows a driver to disable the command if it knows that this command
handling is broken.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This is initial version of
http://tools.ietf.org/html/draft-ietf-6lo-btle-00
By default the 6LoWPAN support is not activated and user
needs to tweak /sys/kernel/debug/bluetooth/hci0/6lowpan
file.
The kernel needs IPv6 support before 6LoWPAN is usable.
Signed-off-by: Jukka Rissanen <jukka.rissanen@linux.intel.com>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Add the LMP feature constants for connectionless slave broadcast
and use them for capability testing.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The Device Under Test (DUT) mode is useful for doing certification
testing and so expose this as debugfs option.
This mode is actually special since you can only enter it. Restoring
normal operation means that a HCI Reset is required. The current mode
value gets tracked as a new device flag and when disabling it, the
correct command to reset the controller is sent.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Enabling and disabling SSP debug mode is useful for development. This
adds a debugfs entry that allows to configure the SSP debug mode.
On purpose this has been implemented as debugfs entry and not a public
API since it is really only useful during testing and development.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This seems to be a left-over. The module parameter enable_hs has
been removed, but its extern declaration is still present. It is
not needed anymore, so just remove it.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The constants for advertising event types have been defined twice. So
remove one copy of it.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
On controller power on and when enabling LE functionality,
make sure that also the scan response data is correctly set.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This patch just adds the HCI command structure for configuring the
current IAC LAP setting. The length of the command is variable and
supports more than two IAC. However since there is only general
discoverable and limited discoverable modes, this can be limited
to two possible IACs.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Add a new flag that can be set when in limited discoverable mode. This
flag will cause the limited discoverable bit in the class of device
value to bet set.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Read the current IAC LAP values when initializing the controller. The
values are not used, but it is good to have them in the trace files
for debugging purposes.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Gustavo Padovan <gustavo.padovan@collabora.co.uk>
When initializing a controller make sure to read out the number of
supported IAC and store its result. This value is needed to determine
if limited discoverable for BR/EDR can be configured or not.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Gustavo Padovan <gustavo.padovan@collabora.co.uk>
When initializing an AMP controller, read its current known location
data so that it can be analyzed later on.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>