Use the macros SYM_FUNC_START() and SYM_FUNC_END() to annotate the
functions in assembly.
Signed-off-by: Jens Remus <jremus@linux.ibm.com>
Signed-off-by: Heiko Carstens <hca@linux.ibm.com>
Acked-by: Vasily Gorbik <gor@linux.ibm.com>
Signed-off-by: Vasily Gorbik <gor@linux.ibm.com>
Clear the backchain of the extra stack frame added by the vdso user wrapper
code. This allows the user stack walker to detect and skip the non-standard
stack frame. Without this an incorrect instruction pointer would be added
to stack traces, and stack frame walking would be continued with a more or
less random back chain.
Fixes: aa44433ac4 ("s390: add USER_STACKTRACE support")
Reviewed-by: Jens Remus <jremus@linux.ibm.com>
Signed-off-by: Heiko Carstens <hca@linux.ibm.com>
Signed-off-by: Alexander Gordeev <agordeev@linux.ibm.com>
Introduce and use struct stack_frame_vdso_wrapper within vdso user wrapper
code. With this structure it is possible to automatically generate an
asm-offset define which can be used to save and restore the return address
of the calling function.
Also use STACK_FRAME_USER_OVERHEAD instead of STACK_FRAME_OVERHEAD to
document that the code works with user space stack frames with the standard
stack frame layout.
Fixes: aa44433ac4 ("s390: add USER_STACKTRACE support")
Reviewed-by: Jens Remus <jremus@linux.ibm.com>
Signed-off-by: Heiko Carstens <hca@linux.ibm.com>
Signed-off-by: Alexander Gordeev <agordeev@linux.ibm.com>
The return-address (RA) register r14 is specified as volatile in the
s390x ELF ABI [1]. Nevertheless proper CFI directives must be provided
for an unwinder to restore the return address, if the RA register
value is changed from its value at function entry, as it is the case.
[1]: s390x ELF ABI, https://github.com/IBM/s390x-abi/releases
Fixes: 4bff8cb545 ("s390: convert to GENERIC_VDSO")
Signed-off-by: Jens Remus <jremus@linux.ibm.com>
Acked-by: Heiko Carstens <hca@linux.ibm.com>
Signed-off-by: Alexander Gordeev <agordeev@linux.ibm.com>
Use __ALIGN instead of open coded .align statement to make sure that
vdso code follows global kernel function alignment rules.
Signed-off-by: Heiko Carstens <hca@linux.ibm.com>
Add minimalistic trampolines to vdso64 so we can return from signal
without using the stack which requires pgm check handler hacks when
NX is enabled.
restart_syscall will be called from vdso to work around the architectural
limitation that the syscall number might be encoded in the svc instruction,
and therefore can not be changed.
Signed-off-by: Sven Schnelle <svens@linux.ibm.com>
Reviewed-by: Heiko Carstens <hca@linux.ibm.com>
Signed-off-by: Vasily Gorbik <gor@linux.ibm.com>
Implement the previously removed getcpu vdso syscall by using the
TOD programmable field to pass the cpu number to user space.
Reviewed-by: Sven Schnelle <svens@linux.ibm.com>
Signed-off-by: Heiko Carstens <hca@linux.ibm.com>
Convert s390 to generic vDSO. There are a few special things on s390:
- vDSO can be called without a stack frame - glibc did this in the past.
So we need to allocate a stackframe on our own.
- The former assembly code used stcke to get the TOD clock and applied
time steering to it. We need to do the same in the new code. This is done
in the architecture specific __arch_get_hw_counter function. The steering
information is stored in an architecure specific area in the vDSO data.
- CPUCLOCK_VIRT is now handled with a syscall fallback, which might
be slower/less accurate than the old implementation.
The getcpu() function stays as an assembly function because there is no
generic implementation and the code is just a few lines.
Performance number from my system do 100 mio gettimeofday() calls:
Plain syscall: 8.6s
Generic VDSO: 1.3s
old ASM VDSO: 1s
So it's a bit slower but still much faster than syscalls.
Signed-off-by: Sven Schnelle <svens@linux.ibm.com>
Reviewed-by: Heiko Carstens <hca@linux.ibm.com>
Signed-off-by: Vasily Gorbik <gor@linux.ibm.com>